Dri-Eaz 103614 (F600) Owner'S Manual Download Page 2

108259F #103614 (F600) 

Legend Brands, Inc. 

upright and let it stand for at least 30 minutes before 

turning it on.  

Positioning a Dehumidifier 

For best results, operate your dehumidifier in 

an enclosed area. Close all doors and windows 

to maximize the unit’s water removal efficiency. 

Place your dehumidifier away from 

obstructions and keep it away from anything 

that could obstruct airflow into and out of the 

unit.  

Extend handle 

Release the handle by rotating red locking 

lever outward, then lift handle up into place. 

Rotate red lever back into locked position to 

secure handle in operating position.  

NOTICE:

 Do not use the extended handle to lift 

the unit off the ground horizontally. Do not use 

the extended handle as an attachment point to 

strap the unit in a vehicle for transport. These 

uses will place undue strain on the handle 

attachment points in the housing. 

Set up drain hose 

This unit automatically pumps out water on a 

regular basis. This dehumidifier is equipped 

with a quick-connect fitting for attachment to 

the provided drain hose located in the tray on 

top of the unit. Unwrap the entire hose and 

place the open end in a sink, drain, bucket or 

outdoors – anywhere that water can drain out 

safely. If you use a bucket or other container 

for water collection, check it regularly to 

prevent overflows. 

NOTICE:

 Uncoil and straighten the entire drain 

hose. Do not leave any part of the hose coiled 

on the unit and do not place the end of the 

hose higher than 20 ft. (6 m) above the bottom 

of the unit. Also check for kinks or other 

obstructions that might restrict the flow of 

water. A kink or blockage will cause the unit to 

turn off and produce an error message on the 

control panel.  

Plug in electrical cord 

The dehumidifier should be plugged into a 

GFCI-protected 115 volt outlet rated for at least 

15

 

amps. Remove the cord from the storage 

tray and uncoil it. Always plug the cord firmly 

into the unit first, and then plug the other end 

into a suitable electrical outlet.  

 

 

 

 

Drain hose 

quick-connect. 

Power cord 

socket.  

Model serial 

number label 

FRONT

 

REAR

 

Humid air inlet. 

Air filter.  

Power cord and 

drain hose 

storage. 

Process (dehumidified) 

air outlet.  

Front panel. Remove to 

access the pump and 

coils for cleaning. See 

Fig. B. 

Integrated handle. Use the 

red lever to lock handle 

upright for use or down 

for loading or storage. 

Control panel. 

FIG A: PARTS IDENTIFICATION

 

Drain hose quick-

connect.  

 

Summary of Contents for 103614 (F600)

Page 1: ...o not use an extension cord The unit must be operated on a 115V 60Hz circuit protected by a Ground Fault Circuit Interrupter GFCI device Keep motor and wiring dry Do not attempt to repair the unit For...

Page 2: ...e entire hose and place the open end in a sink drain bucket or outdoors anywhere that water can drain out safely If you use a bucket or other container for water collection check it regularly to preve...

Page 3: ...plugged in Top display bar Job hours current time Press MENU to access settings and configuration controls Press PURGE to pump out condensate tank Press ON OFF to turn unit on Unit ON Press ON OFF ke...

Page 4: ...BLE Error W3 Flash Reset W4 WDT Reset Cycle power to dehumidifier If warning persists contact service AT THE END OF THE JOB To reduce the possibility of drips when moving the unit follow these additi...

Page 5: ...ss drill small knife small jaw pliers coil cleaning solution rotomolded housing cleaning solution Before each use Inspect the electrical cord for damage Look for fraying cuts etc Replace the cord if y...

Page 6: ...istance SPECIFICATIONS Model LGR 6000Li 103614 F600 Water removal AHAM 80 F 60 RH 100 pts 47 3 L day Water removal saturation 90 F 90 RH 204 pts 96 5 L day Process air max 320 CFM Dimensions H D W 32...

Page 7: ...o lo use Siempre sostenga el enchufe no el cable para desenchufar Inserte el enchufe de tres patas en un tomacorriente correspondiente con puesta a tierra No use un adaptador Nunca corte la tercera pa...

Page 8: ...a para su conexi n a la manguera de drenaje provista de 40 pies 12 m ubicado en la bandeja sobre la unidad Desenrolle la manguera completamente y coloque el extremo abierto en un lavabo drenaje cubo o...

Page 9: ...ara acceder a los controles de ajustes y configuraciones Presione PURGA para vaciar el tanque de condensado Presione ENCENDER APAGAR para encender la unidad Unidad ENCENDIDA Presione la tecla ENCENDER...

Page 10: ...rriente Si el error contin a comun quese con el servicio t cnico ER9 Error Bomba Obstruida Compruebe que no haya obstrucciones La manguera est acodada debajo de la unidad o aplastada por una rueda Ver...

Page 11: ...manual Destornillador Philips Broca T 20 Torx Llave para tuercas o llave de cubo y trinquete 10 mm Pa os de limpieza Aspiradora HEPA con una boquilla con cepillo blando y herramienta para cavidades Re...

Page 12: ...LGR 6000Li 103614 F600 Extracci n de agua AHAM 80 F 60 de humedad relativa 100 pintas 47 3 l d a Saturaci n de la extracci n de agua 90 F 90 de humedad relativa 204 pintas 96 5 l d a Dimensiones altur...

Page 13: ...ours la prise pas le c ble pour d brancher Ins rez la fiche triphas e du c ble d alimentation dans une prise de terre correspondante N utilisez pas d adaptateur Ne coupez jamais la troisi me broche N...

Page 14: ...ation pour attacher l unit dans un v hicule pour le transport Une telle utilisation exerce une pression excessive sur les points d attache de la poign e dans le logement Mise en place du tuyau de vida...

Page 15: ...res veuillez visiter la page du Contr leur i Series sur Controller LegendBrandsRestoration com Affichages cran d accueil Unit FERM E L unit doit tre branch e Barre d affichage sup rieure Heures de tra...

Page 16: ...loqu e V rifiez s il y a des obstructions Est ce que le tuyau est tordu sous l unit ou coinc sous une roue V rifiez que la pompe n est pas obstru e et corrigez si n cessaire W1 Basse BATTERIE Remplace...

Page 17: ...ou douille et cliquet Chiffons de nettoyage Aspirateur HEPA avec embout brosse douce et suceur plat Recommand Perceuse sans fil petit couteau petites pinces solution de nettoyage de serpentin solution...

Page 18: ...ECHNIQUES Mod le LGR 6000Li 103614 F600 limination de l eau AHAM 80 F 60 RH 100 pts 47 3 L jour limination de l eau Saturation 90 F 90 RH 204 pts 96 5 L jour Air de traitement max 320 CFM Dimensions H...