aerosmart - Operation, Maintenance and Commissioning
Page 4
Operation
The unit is controlled, managed and operated via a micro-processor controller on the unit and a
room operating panel. Two types of room operating panels are available:
Analogue room operating panel with heating mode
•
Digital room operating panel
•
If the analogue room operating panel is used, the basic settings must be made on the compact
unit (micro-processor controller) during commissioning.
If the digital room operating panel is used; the settings can all be made on either the room operat-
ing panel or the micro-processor controller.
Micro-Processor Controller
The micro-processor controller is located on the ventilation module. It manages the ven-
tilation, room heating and the heating of the domestic hot water.
'Alarm' button: this button illuminates red if the controller transmits an error message.
1.
Press the button to acknowledge the fault.
'Prg' button: is only required to program the software.
2.
'Esc' button: use this button to exit a program item or a menu.
3.
'
4.
↵
' (Enter) button: use this button to confi rm selected values, settings or menu items.
'
5.
↑
' arrow key: for scrolling in the menu. Use this button to select individual menu
items and amend the values.
'
6.
↓
' arrow key: for scrolling in the menu. Use this button to select individual menu
items and amend their values.
Display: the four-line display shows settings and various measurements.
7.