3-12
Specifications
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
ENVIRONMENTAL SPECIFICATIONS
and
describe the environmental specifications of the HPG
generator.
Table 3-4. Climatic specifications
Temperature
Relative Humidity
Air Pressure
Operating
5
°
C to +35
°
C
+41
°
F to +95
°
F
Class 3K2
10% to 85%
Note
1
+2 g/m
3
to
+25 g per m
3
Class 3K3
80 kPa to 106 kPa
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Storage
Class 1K4
-25
°
C to +55
°
C
-13
°
F to +131
°
F
Class 1K3
5% to 95%
+1 g per m
3
to
+29 g per m
3
Class 1K4
80 kPa to 106 kPa
800 mbar to 1060 mbar
(approximately 2000 m
above sea level)
Transportation
Class 2K3
-25
°
C to +70
°
C
-13
°
F to +158
°
F
Class 2K3
95%
Note
2
+60 g per m
3
Note
3
Class 2K3
66 kPa to 106 kPa
660 mbar to 1060 mbar
(approximately 3265 m
above sea level)
Note
1
Noncondensing
Note
2
Maximum relative humidity when the unit temperature slowly increases, or when
the unit temperature directly increases from -25°C to +30°C
Note
3
Maximum absolute humidity when the unit temperature directly decreases from
+70°C to +15°C
Table 3-5. Environmental specifications
Description
Specification
Overvoltage
Category II
Pollution
Degree 2
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...