Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 22 of 74
8.
Tilt and slide the top AMR mounting bracket over
the tabs of the base AMR mounting bracket.
Figure 24: Slide on the top AMR mounting
bracket
9.
Verify there are no gaps or wires between the top
and base AMR mounting brackets.
Figure 25: Check for gap between the top and
base AMR mounting brackets
10.
Insert the screws into position to attach the top
AMR mounting bracket to the back of the digital
index, and tighten the screws to a maximum torque
of 18 inch pounds.
Figure 26: Attach top AMR mounting bracket
screws