DResearch – User Manual TeleObserver MR3140
2011-02-03
61
Audio interface
Audio input
Connectors:
D-Sub-9 socket (female)
Number:
1
Signal level (max., peak-peak):
2,8 V (+2 dBu), 0,5 V (-13 dBu) with input amplifier
Input impedance:
>10 kOhm
Frequency response (+/-3 dB):
100 Hz … 10 kHz
Digital interfaces
Digital inputs
Connectors:
D-Sub-25-socket (female)
Number:
6
Input level:
Low: 0 ... 3 V
High: 6 ... 34 V
Ingnition input
Number:
1 (differential)
Differential input levels:
Low: 0… 3V
High: 6... 34V
Digital outputs
Connectors:
D-Sub-25-socket (female)
Number:
4 relays (SPDT)
Capacity:
60 V DC, 125 V AC, 500 mA
Picture data transmission
Communication links
Transmission rate
Bandwidth
LAN/Ethernet
25 pictures/s
100 Mbit/s
WLAN
25 pictures/s
54 Mbit/s
Other interfaces
RS232
D-Sub-9-socket (male)
RS485
D-Sub-25- socket (male)
Ethernet
1 x RJ45 (LAN 1), 100 Mbit as service interface
IBIS
D-Sub-25- socket (male)
LED
4 (status conditions: off, red, yellow, green)