DResearch – User Manual TeleObserver MR3140
2011-02-03
20
2.4.3.2
Display of information and system events (OSD)
Using OnScreenDisplay the recorder shows additional information in the form of symbols and texts
when particular system events and alarms occur. The following information and system events are
displayed:
Symbol
Significance
Description
Name of the warning device
Symbols for the six digital inputs IN1 to IN6.
Displays the number of the active alarm or
electromechanical lock at the bottom of the
screen.
⊗
-
Alarm in the last hour.
Automatically increases the duration if another
alarm is activated or deactivated within this
period.
*
Alarm recording active
Alarm sequence recording.
HD (!)
No disk found
No disk or disk faulty.
HD (60%)
HD (80%)
Alarm archives 60% full
Alarm archives 80% full
At least 60% (or 80%) of the hard disk
capacity has been written with alarm footage.
HD (full)
Alarm archives full
No further alarm sequence recording possible.
Archiving and release of the alarm archive in
ImageFinder.
GPS
GPS fault
Device is not receiving GPS signal.
IBIS
IBIS-Bus fault
Device is not receiving IBIS signal.
RMC
RMC fault
Fault in the Rail Media Coupler.
IP (1..8)
Camera number
IP camera video signal missing.
A (1..4)
Camera number
Analogue camera video signal missing or
camera has been sabotaged or covered.
(A = camera group A = 1..4)
Alarm system conditions and events indicators