Preparation
NOTE:
This enclosure is reversible for right or left-hand return panel installation. The
right-hand return panel installation is shown as an example throughout this manual. For the
left –hand return panel installation, simply begin on the opposite wall and reverse the
orientation of the steps shown.
1. Prior to installation, examine all boxes and packages for shipping damage and compare the piece count with
the packing slip. After opening all boxes and packages read this introduction carefully. Check that all of the
necessary parts are included in the package by checking off the components on the “Detailed Diagram of Shower
Door Components”. If the unit has been damaged, has a finishing defect, or has missing parts, please contact our
customer support department within
3 business days
of the delivery date.
Please note that DreamLine
®
will
not replace any damaged products or missing parts free of charge after 3 business days or if the product
has been installed.
Contact DreamLine
®
if you have any questions, and please provide an order number, job
name or other proof of purchase to help identify the original order.
2.
Please note that you should consult your local building codes with questions on installation
compliance standards. Building and plumbing codes may vary by location, and DreamLine
®
is not
responsible for code compliance standards for your project and will not accept any returns.
3. If this unit is going to be installed in a new construction, please install all of the required plumbing and
drainage before installing the shower. Use a competent and licensed (if required by local code) plumber for all
plumbing installation
4. Please make sure that prior to beginning the installation, the surfaces are leveled and solid and will be able to
support the total weight of the unit. Also make sure the walls are at right angles. Irregular installation surface
level, radius corners or improper angle of side walls will result in serious problems for your installation. Note that
some adjustments and drilling will be necessary during the installation process.
5. Please protect all primary surfaces of the product during installation. Never set the glass down directly onto a
tile floor. Leave corner protectors in place until necessary to remove them. Always use a piece of wood or
cardboard to protect the bottom edge and corners of the glass prior to and during installation.
6. This unit must be installed upon a finished threshold and against finished walls.
7.
This model does NOT have any adjustment for out of plumb conditions. Verify that your walls are
plumb before proceeding with the installation.
8.
This model requires that you drill into the threshold for proper installation.
9.
This model is offered in two styles with either Support Bars or L-Bars™. Follow the proper steps to
complete the installation based on the model ordered (see note on page #9).
10. This model requires a minumum of
1-1/2”
of flat threshold space for installation.
11. The installtion of this product requires two installers.
12.
Professional installation recommended.
!
!
NOTE:
Do Not
attach the handle to the door glass until instructed.
Do Not
attempt to lift the door glass with the handle as this may result in damage to the
glass and/or serious personal injury. Use a professional grade glass suction cup and an
assistant when handling heavy glass.
3
QUATRA LUX 32x46 34x46 shower enclosure manual Ver 3 Rev 4a 112019
©2019 DreamLine. All Rights Reserved