Installation steps
6
MIRAGE-X manual Ver 1 Rev 1 12/2015
Fig 1
Fig 2
L
L
1.
Measure the finished opening at the top,
middle and bottom.
The bottom width dimension will be “W”.
Also check the threshold for level and the
walls for plumb.
Note that this model does not have
adjustment for out-of-plumb conditions.
See Fig 1 for details
2.
Subtract 1/16” from your “W” dimension.
(W-1/16” = L) “L” = finished cut length.
Use a miter saw or hack saw to cut your
Bottom Guide Rail (#03) to the finished cut
length “L”.
NOTE: Cut from the end of the rail that will
be on the door side.
See Fig 2 for details
NOTE: If it is necessary to drill new attachment holes into
the bottom guide rail after cutting to size : drill a Ø3/16”
hole throughout and then a Ø5/16” hole through the top
layer only. (Refer to the existing holes in the rail for example)