18.
Attach two
Roller assemblies (04)
to the
Glass door (05)
.
Suspend the door by hanging the
Rollers
onto the
Upper
guide rail (03)
and slide the bottom edge of the
Glass
door
into the groove of the
Guide block (12)
.
See Fig. 21 for details.
Fig.
20
Fig. 21
19.
Press the
Anti-water strip (14)
on the vertical edges of
the
Stationary glass (02)
and the
Glass door (05).
Also
press the
Bumper strip (13)
on the vertical edge of the
Glass door.
Mount the
Handle (06)
to the
Glass door.
Adjust both
Door stoppers (01
) to ensure that they are
positioned upright and the
Glass door
is in its maximum
opening and closing range. Tighten the set screw to
fasten them in place.
Adjust the
Roller guards
on both
Roller assemblies
to
ensure that the
Glass door
is secure to the
Upper guide
rail
.
See Fig. 22 for details.
Fig.
22
2