- 11 -
Mounting - 8 x M10
Figure 9
2.2.3
WIRING FOR: OKCE 160 S/2,2 KW, OKCE 160 S/3-6 KW, OKCE 200 S/2,2 KW, OKCE
200 S/3-6 KW, OKCE 250 S/2,2 KW, OKCE 250 S/3-6 KW, OKCE 300 S/1 MPA ,
OKCE 400 S/1 MPA, OKCE 500 S/1 MPA
Water heater is equipped with a universal electric heating unit with either a set or adjustable heating
elements' performance (except OKCE 300 S/1 MPa). A heating unit consists of a flange, to which one or
three wells for ceramic heating elements and one thermowell are welded (viz. Figure 10, Figure 11, Figure
12). A unit is attached by either 8 M 10 screws with a 168 mm clearance or 12 M 12 screws with a 210 mm
clearance. In the wiring plastic cover, there is a thermostat and a safety fuse; heater operation control light;
and a lead-in wire bushing.
The sensors must be inserted all the way in; first the thermostat and then the safety
fuse.
The performance of heating unit may be adjusted based on either required heating time or connecting
possibilities of electric energy distribution in the place of use.
Parameters of an electric heating unit for: OKCE 160 S/2,2 kW, OKCE 160 S/3-6 kW, OKCE 200 S/2,2 kW,
OKCE 200 S/3-6 kW, OKCE 250 S/2,2 kW, OKCE 250 S/3-6 kW
Type
Performance
(kW)
Voltage (V/Hz)
Build-up
length l (mm)
IP
Protection
Weight
(kg)
Mounting
TPK 168 - 8/2,2 kW
2,2
1 PE-N ~
230 V/50 Hz
405
IP 44
5
8 x M10
Table 3
For: OKCE 300 S/1 MPa – the heating element has to be additionally purchased
Type
Performance
(kW)
Voltage (V/Hz)
Build-up
length l (mm)
IP
Protection
Weight
(kg)
Mounting
TPK 210 - 12/2,2 kW
2,2
1 PE-N ~
230 V/50 Hz
440
IP 44
9
12 x M12
TPK 210 - 12/3-6 kW
3 - 4 - 6
3 PE-N ~ 400 V/50 Hz
440
IP 44
15
12 x M12
TPK 210 - 12/5-9 kW
5 - 7 - 9
3 PE-N ~ 400 V/50 Hz
550
IP 44
18
12 x M12
TPK 210 - 12/8-12 kW
8 - 10 - 12
3 PE-N ~ 400 V/50 Hz
550
IP 44
18
12 x M12
Table 4