- 10 -
2.2
ELECTRIC INSTALLATION
2.2.1
GENERAL INFORMATION FOR ELECTRIC INSTALLATION
Perform the connection according to the scheme. Factory connection must not be changed! (Figure 8). In
the electric wiring casing remove the partition corresponding with the input wire diameter of
8 or
10
(Figure 7). The degree of protection of electric parts of the heater is IP 45. Power input of electric element
is 2000 W.
Figure 7
2.2.2
WIRING FOR: OKCE 100 S/2,2 KW, OKCE 125 S/2,2 KW
Wiring scheme is attached to the heater wiring on the cover.
Connect, repair and control wiring can be performed only company authorized for this activity.
Professional involvement must be confirmed by the warranty.
The heater is connected to the power supply 230 V/50 Hz movable fixed wire which is equipped with all-
pole disconnecting switch network and circuit breaker (protector).
Wiring scheme:
Figure 8