9
-
1.
The coolant R134a is compressed in a highly efficient compressor that increases its pressure
and temperature.
2.
In a capacitor that is not in direct contact with water, the thermal energy contained in the coolant
is transferred to the water in the hot water storage tank.
3.
Condensed liquid flows from the expansion valve that is responsible for a drop in its pressure.
4.
The fluid absorbs thermal energy from the air flowing through the evaporator with the help of a fan.
R134a is a HFC coolant, and therefore does not damage the ozone layer. It is characterized
by excellent chemical and thermal stability, low toxicity, is not flammable and is compatible
with most materials.
2.3
TECHNICAL PARAMETERS
Unit
250 I
Type of appliance
Water heater with heat pump
Hot water volume
L
250
Weight without water
kg
83
Material of upper part
-
Stainless steel
Tank shell material
-
Steel sheet
Insulation
-
Polyurethane foam 50 mm
Mg anode
-
1”
Maximum service temperature
°C
80
Maximum service pressure
MPa (bar)
7
Test pressure
MPa (bar)
10
Heat loss
kWh/ annum
0,99
Tubular heat exchanger (diameter / length)
m
-
/
-
Exchanger power output
1)
kW
-
IP Protection
-
IPX1
Supply voltage
-
1/N/PE ~ 230V/50Hz
Input (medium / maximum)
W
400 / 700
Output of the electrical heating element
W
1500
Heat pump
output
W
1800
Fan input
W
65
Maximum service current
A
3.2 + 6.8 (with backup electrical heating)
Recommended breaker
-
16A (sensitivity 30 mA)
Max temperature of hot water for heat pump
°C
55
Max temperature of hot water for heating element
°C
65
Coolant
-
/kg
R 134a / 1.2
Load profile
-
XL
COP
2)
-
3.24
Heating time
2)
HH:mm
6:48
Volume of usable water 40 °C
2)
l
314
Energy efficiency class
2)
-
A+
Energy efficiency
2)
%
138
Annual energy consumption
2)
kWh . a
-
1
1251
Ambient temperature limit values
°C
-
5 / 40
Acoustic pressure level
dB(A)
51
Airflow
m
3
/h
450
Maximum length of air technical manifold
m
10