Draper Access XL E Instructions Manual Download Page 6

Section 9.2 - ILT Motors with Internal Low-Voltage Control Limit Adjustments 

(Fig. 12)

1.  

Connect ILT switch to motor via terminal blocks, or via 

modular port using a four conductor modular cable. When 

using modular cable, cable connectors MUST NOT be 

crimped in reverse, as with standard telephone cable.  

(For Dry Contacts Wiring Diagram, see Section 12.)

2.  

Set slide switch to lower position. Hold DOWN button to 

move viewing surface to desired lower limit. If screen moves 

in opposite direction, release DOWN button and hold STOP 

button for 4 seconds. This reverses operation of UP and 

DOWN switches.

3.  

Move slide switch into center position. Wait several seconds.

Please Note:

 

Do Not

 move slide switch from DOWN to UP  

in one motion. This will set limits in same position.

4.  

Set slide switch to higher position. Move viewing surface to 

desired upper limit by holding UP button on wall switch.

5. 

Return slide switch to center position to resume normal 

operation.

6. 

To set viewing surface to alternate format position, move 

viewing surface to desired position and press STOP button. 

Hold STOP button for at least 3 seconds to record position.

Please Note:

 Press and release UP 

button on switch to move screen to 

upper limit. Press and release DOWN 

button to move screen to lower limit.

• While motor is in motion, press 

STOP button for less than 2 

seconds to stop viewing surface at 

present position.

• Once motor is stopped, press 

STOP button to move viewing 

surface to alternate format position.

• Hold STOP button, when motor is 

at rest or in motion, for 3-5 

seconds to record new alternate 

format position.

• Hold STOP button for 3-5 seconds 

while in programming mode to 

reverse motor direction.

POSITION

FUNCTION

DOWN

Set LOWER limit

UP

Set UPPER limit

CENTER

Normal Operation

Please Note:

 5V DC must be connected to 

be able to set limits using the wall switch.

BACK VIEW OF WALL SWITCH

U

p

D

o

w

n

C

o

m

m

o

n

+

5V

DC

To Motor

with

Built-In (ILT)

Low Voltage

Slide

Switch

To Motor

with

Built-In (ILT)

Low Voltage

Please Note:

 Hold STOP button for 3-5 seconds while in programming mode to reverse motor direction.

Figure 12

Section 9 -

 Limit Adjustments

Figure 11

Figure 10

Section 9.1 - Standard Motors Limit Adjustments 

(Fig. 10)

Section 9.1.1 - "Down" Limit Adjustment 

(requires 

5/32

" (4 mm) Hex key)

To Reduce Screen Drop:

1. 

Raise screen surface approximately 1' 

(30 cm)

 above desired setting  

and turn off.

2. 

Turn DOWN 

(I)

 limit screw clockwise 

(3 screw turns = 

1/2

 roller revolution)

.

3. 

Test by lowering screen. Repeat steps 1 & 2 until desired position  

is reached.

To Increase Screen Drop:

1. 

Lower screen to down limit.

2. 

With down switch on, turn DOWN 

(I)

 limit screw counterclockwise  

(3 screw turns = 1/2 roller revolution) 

to increase drop.

3. 

Test by raising screen approximately 1' 

(30 cm)

 then down to new  

down limit.

4. 

Repeat steps 2 and 3 until desired position reached.

Section 9.1.2 - "Up" Limit Adjustment

If Screen Raises Too High:

1. 

Lower screen surface approx. 1' 

(30 cm)

 below desired setting and turn off.

2. 

Turn UP 

(II)

 limit screw clockwise  

(3 screw turns = 1/2 roller revolution).

3. 

Test by advancing screen up.

4.  

Repeat steps 1 through 3 until desired position is reached.

If Screen Needs to Raise Higher:

1.  

Lower screen surface approx. 1' 

(30 cm)

 below desired setting and turn off.

2.  

With UP switch on, turn UP 

(II)

 limit screw counterclockwise  

(3 screw turns = 

1/2

 roller revolution)

.

3.  

Repeat steps 1 and 2 until desired position is reached.

 CAUTION:

 DO NOT allow dowel to wrap over roller when operating screen!  

This could damage screen.

Please Note:

 Screen limits 

are factory set for optimum 

performance of the screen. Any 

adjustment of these limits could 

void the warranty. Please check 

with Draper prior to resetting 

screen limits.

Please Note:

 If screen is “Right 

Hand Motor,” the WHITE/DOWN 

(I)

 and YELLOW/UP 

(II)

 limit 

screws are reversed 

(Fig. 11)

.

 CAUTION:

- Be sure all switches are in “off” 

position before adjusting limit 

switches.

- Be prepared to shut off manually 

while testing.

- Screen may be damaged by 

lowering it too far and  

exposing roller.

- Motor must be installed so that 

limit switches are pointed down.

Left hand motor:

   White Socket—Down

   Yellow Socket—Up

Right hand motor:

   White Socket—Up

   Yellow Socket—Down

Left hand motor:

   White Socket—Up

   Yellow Socket—Down

Right hand motor:

   White Socket—Down

   Yellow Socket—Up

Left hand motor:

  White Socket—Down

  Yellow Socket—Up

Right hand motor:

  White Socket—Up

  Yellow Socket—Down

Waterfall Roll

Standard Roll

Motor

End

Audience

Side

Motor

End

Audience

Side

Reverse Roll

Motor

End

Back

Side

lI

I

+

+

DOWN Limit (I)

Clockwise decreases 

down 

travel.

UP Limit (II)

Counterclockwise

increases 

up 

travel.

DOWN Limit

 

(I)

Clockwise 

decreases  

down

 travel.

UP Limit 

(II)

Counterclockwise 

increases 

up

 travel.

page 6 of 8

Access XL E and V 220V

Summary of Contents for Access XL E

Page 1: ...3 Bottom Access XL Panel Installation Removal 4 Section 4 Motorized Roller Fabric Installation 4 Section 5 Motorized Roller Fabric Removal 5 Section 6 Tab Tension Adjustment Procedure 5 Section 7 Oper...

Page 2: ...Canadian Electrical Code Part 1 CSA C22 1 11 Connections must be made in accordance with attached wiring diagram and wiring must comply with national and local electrical codes 12 All operating switch...

Page 3: ...ILING INSTALLATION Additional set of brackets required but NOT included HOUSING HOUSING HOISTING BRACKET not to be used for final installation TWO CASE MOUNTING BRACKETS Per End 7 8 22mm CABLE EXIT CA...

Page 4: ...from brackets 9 Center roller fabric assembly by sliding mounting brackets left or right 10 Securely tighten set screws on roller mounting brackets 11 Connect electrical plug from motor to mating sock...

Page 5: ...removal of unit Section 6 Operation CAUTION When operating for the first time cycle unit down and up several times to confirm satisfactory operation Be prepared to cut POWER if necessary 220V SINGLE S...

Page 6: ...32 4 mm Hex key To Reduce Screen Drop 1 Raise screen surface approximately 1 30 cm above desired setting and turn off 2 Turn DOWN I limit screw clockwise 3 screw turns 1 2 roller revolution 3 Test by...

Page 7: ...re several knock outs in the screen housing to allow the Leveling Bracket to be adjusted laterally up to 16 40 6cm in either direction Section 11 Case Width Dimensions ACCESS X 18 457mm 18 457mm 19mm...

Page 8: ...to screen directional Yellow to 230V AC Hot Black to 230V AC Hot Green Yellow Ground Blue Common Brown Down Black Up Internal Screen Wiring Electrically Straight Data Cable to more LVC IV modules A m...

Reviews: