Section 8 -
Electrical Connections
CAUTION:
All operating switches should be "off" before power is connected. Plug-in power cord option available with built-in low-voltage motor.
•
Screen operates on 220-240V, 50 Hz., 0.6 Amp current draw. Duty cycle: On 28 seconds/Off 4 minutes.
•
Junction box is located inside left endcap and cover plate secures to endcap with two screws which may be removed with star key or small flat head screwdriver.
Junction box contains red, black, and white pigtail leads and green internal ground wire, per wiring diagram.
•
Screen ships complete with internal wiring. Control switch
(es)
may be packed in cartons separate from screen. Wire connecting screen to switch
(es)
and switch
(es)
to power supply furnished by installer. Connections must be made in accordance with attached wiring diagram
(s)
, and wiring must comply with national and local
electrical codes.
Please Note:
Screen must be installed in accordance with the requirements of the Local Building Codes, the Canadian Electrical Code
(CEC)
, CAN/CSA C22.1,
and the National Electric Code
(NEC)
, NFPA 70. An appropriate disconnect device shall be provided as part of the building installation.
Please Note:
Do NOT wire motors in parallel.
Section 5 -
Motorized Roller/Fabric Removal
Reverse the previous instructions
("Motorized Roller/Fabric Installation")
for removal of unit.
Section 6 -
Operation
CAUTION:
When operating for the first time, cycle unit down and up several times to confirm satisfactory operation. Be prepared to cut POWER if necessary.
• 220V SINGLE STATION CONTROL -
3-position UP-OFF-DOWN switch permits operation to be stopped at any point. Factory adjusted limit switches
automatically stop screen when fully down or fully up.
• 24V CONTROL -
3-button UP-STOP-DOWN switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop
screen when fully up or fully down. Installer should incorporate an all-pole disconnect in fixed wiring available with RF or IR remote.
• KEY OPERATED SWITCHING -
Two key-operated switches optionally available with this unit:
• Key-operated power supply switch
controls power to screen and switches. When “off”, switches will not operate screen. Key may be removed from switch
in either "on" or "off" position.
• 3-position key switch
permits the screen to be operated directly by key. Requires screen operator to have a key.
• RS232 / ETHERNET -
Serial communication and network communication optionally available.
Section 7 -
Tab-Tension Adjustment Procedure
Please Note:
Draper Tab-Tensioning System is factory-set, and under normal circumstances will not require field
adjustments. If wrinkles are observed, follow the adjustment procedure shown in Fig. 8.
PUSH & TURN
CLOCKWISE
to INCREASE TENSION
PUSH & TURN
COUNTER-CLOCKWISE
to RELEASE TENSION
END OF
DOWEL
END OF
DOWEL
Figure 8
page 5 of 8
Access XL E and V 220V