POWER SUPPLY

CONNECTING YOUR MACHINE TO THE POWER SUPPLY: 230V

To eliminate the possibility of an electric shock, your machine has been fitted with a BS approved,
non rewireable moulded 3 pin plug and cable which incorporates a fuse, the value of which is
indicated on the pin face of the plug. Should the fuse need to be replaced an          approved
BS1362 fuse must be used of the same rating, marked thus          .

The fuse cover is detachable, never use the plug with the cover omitted. If a replacement fuse
cover is required, ensure it is of the same colour as that visible on the pin face of the plug (i.e.
red). Fuse covers are available from your Draper Tools stockist.

If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the cable should
now be suitably prepared and the correct type of plug fitted. See below.

WARNING: THIS APPLIANCE IS DOUBLE INSULATED.

Blue – Neutral, Brown – Live.
As these colours may not correspond with the coloured markings identifying the terminals in your
plug, proceed as follows:
The wire which is coloured blue must be connected to the terminal which is marked with the letter
‘N’ or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked with the
letter ‘L’ or coloured red or brown

*WARNING:

A plug with bare flexible wires exposed is hazardous if engaged in a live power socket outlet.

WARNING: THIS APPLIANCE MUST BE EARTHED.
Green and Yellow - Earth, Blue - Neutral, Brown - Live.
As these colours may not correspond with the coloured markings identifying the terminals in your
plug, proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal in the plug which
is marked with the letter ‘E’ or by the earth symbol

or coloured green or green and yellow.

The wire which is coloured blue must be connected to the terminal which is marked with the letter
‘N’ or coloured black or blue.

The wire which is coloured brown must be connected to the terminal which is marked with the
letter ‘L’ or coloured red or brown.

N.B.

Three phase machines must be connected by a qualified electrician.

EXTENSION LEAD CHART:
Extension lead sizes shown assure a voltage drop of not more than 5% at rated load of tool.

Ampere rating

3

6

10

13

(on Name plate)

7.5m

0.75

0.75

1.0

1.25

15m

0.75

0.75

1.0

1.5

22.5m

0.75

0.75

1.0

1.5

30m

0.75

0.75

1.25

1.5

45m

0.75

1.25

1.5

2.5

Extension Cable Length

Wire Size mm

2

Summary of Contents for 64261

Page 1: ...r which this tool has been designed and contains all the necessary information to ensure its correct and safe use We recommend that this manual is read before any operation of the machine before perfo...

Page 2: ...er s Ford Eastleigh Hampshire SO53 1YF England Declare under our sole responsibility that the product Stock No 64261 Part No HG2000 Description Hot Air Gun To which this declaration relates is in conf...

Page 3: ...t please return the complete tool to your nearest distributor or contact Draper Tools Limited Hursley Road Chandler s Ford Eastleigh Hampshire SO53 1YF England Telephone 023 8026 6355 If upon inspecti...

Page 4: ...d with the letter N or coloured black or blue The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red or brown WARNING A plug with bare fle...

Page 5: ...ng accessories such as cutters etc 16 AVOID ACCIDENTAL STARTING Make sure the switch is in the OFF position before plugging the machine into the power supply 17 NEVER LEAVE MACHINE RUNNING UNATTENDED...

Page 6: ...ain plastics paints or similar materials 8 When working with or near easily combustible materials and inflammable gases take special care Do not apply heat to any one area for long periods of time 9 H...

Page 7: ...sition For low heat switch up to position 1 for full heat switch into position 2 FREESTANDING OPERATION This hot air gun can be positioned as shown in Fig 2 using the free standing support plate This...

Page 8: ...t air gun should be switched off and disconnected from the power supply allowing the machine to totally cool down before restarting work Remember the nozzle will remain hot for sometime a safe storage...

Page 9: ...s page 9 Switch the hot air gun on to the higher heat setting 2 gently heat the frozen area of the pipe starting from the edge of the area and moving in towards the centre IMPORTANT take care not to h...

Page 10: ...pairs adjustments should be carried out by a qualified person DRAPER HELPLINE 023 8049 4344 MAINTENANCE The following accessories are available from your local Draper Stockist OPTIONAL ACCESSORIES GLA...

Page 11: ...NOTES 10...

Page 12: ...ral Enquiries 023 8026 6355 Fax 023 8026 0784 Published by Draper Tools Ltd No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electr...

Reviews: