4. INTRODUCTION
4.1 SCOPE
This heater is designed to heat large, semi-open areas by means of combustion of Diesel or
Kerosene fuel, and is electrically operated. Any other application is considered mis-use.
4.2 SPECIFICATION
Stock no .................................... 32284 ................................32285 ............................... 53925
Part no ....................................DSH1750 .......................... DSH1250 ...........................DSH2150
Motor:
Rated
voltage
............... 230V~............................... 230V~ ...............................230V~
Rated
frequency
........... 50Hz................................. 50Hz ................................. 50Hz
Rated input .................. 500W................................330W................................ 271W
Heat output .................. 175,000 BTU/51kW .......... 125,000 BTU/36kW.......... 215,000 BTU/62kW
Air flow ................................. 508m
3
/Hr .......................... 480m
3
/Hr......................... 1,100m
3
/Hr
Fuel ............................... Diesel/Kerosene............... Diesel/Kerosene ...............Diesel/Kerosene
Diesel consumption ................ 5Ltrs/hr............................3.6Ltrs/hr.......................... 6.2Ltrs/hr
Tank capacity ............................ 50Ltr................................. 40Ltr.................................50Ltr
Internal shut off temp. ........ 80°C ±10°C....................... 80°C ±10°C ....................... 80°C ±10°C
Reset Temp. .......................... 70°C ±10°C....................... 70°C ±10°C ....................... 70°C ±10°C
Weight .....................................27.2kg .............................. 24.4kg................................ 32kg
Dimensions ..................... 1050x445x540mm .............890x405x510mm ............ 1030x430x550mm
Stock no .................................... 32286 ................................53926 ............................... 32287
Part no .....................................DSH750 ............................ DSH751 ............................DSH450
Motor:
Rated
voltage
............... 230V~............................... 230V~ ...............................230V~
Rated
frequency
........... 50Hz................................. 50Hz ................................. 50Hz
Rated
input
.................. 300W ................................300W................................300W
Heat output ................... 75,000 BTU/22kW ............ 75,000 BTU/22kW............ 45,000 BTU/13kW
Air flow ................................. 399m
3
/Hr .......................... 399m
3
/Hr.......................... 205m
3
/Hr
Fuel ............................... Diesel/Kerosene............... Diesel/Kerosene ...............Diesel/Kerosene
Diesel consumption .............. 2.1Ltrs/hr..........................2.1Ltrs/hr.......................... 1.3Ltrs/hr
Tank capacity ............................ 20Ltr................................. 20Ltr.................................20Ltr
Internal shut off temp. ........ 80°C ±10°C....................... 80°C ±10°C ....................... 80°C ±10°C
Reset Temp. .......................... 70°C ±10°C....................... 70°C ±10°C ....................... 70°C ±10°C
Weight .....................................12.8kg .............................. 14.5kg...............................12.7kg
Dimensions ...................... 800x420x340mm ..............800x420x340mm ............. 800x420x340mm
4.3 HANDLING & STORAGE
The environment will have a negative result on its operation if you are not careful. If the air is
damp, components will rust. If the machine is unprotected from dust and debris; components
will become clogged: And if not cleaned and maintained correctly or regularly the machine
will not perform at its best.
5