3. GUARANTEE

3.1    GUARANTEE

Draper tools have been carefully tested and inspected before shipment and are guaranteed to 
be free from defective materials and workmanship.
Should the tool develop a fault, please return the complete tool to your nearest distributor or 
contact Draper Tools Limited, Chandler's Ford, Eastleigh, Hampshire, SO53 1YF. England. 
Telephone Sales Desk: (023) 8049 4333 or Product Help Line (023) 8049 4344.
A proof of purchase must be provided with the tool.
If upon inspection it is found that the fault occurring is due to defective materials or 
workmanship, repairs will be carried out free of charge. This guarantee period covering 
parts/labour is 12 months from the date of purchase except where tools are hired out when the 
guarantee period is 90 days from the date of purchase. The guarantee is extended to 24 months 
for parts only. This guarantee does not apply to normal wear and tear, nor does it cover any 
damage caused by misuse, careless or unsafe handling, alterations, accidents, or repairs 
attempted or made by any personnel other than the authorised Draper warranty repair agent.
Note: If the tool is found not to be within the terms of warranty, repairs and carriage charges 
will be quoted and made accordingly.
This guarantee applies in lieu of any other guarantee expressed or implied and variations of its 
terms are not authorised.
Your Draper guarantee is not effective unless you can produce upon request a dated receipt or 
invoice to verify your proof of purchase within the guarantee period.
Please note that this guarantee is an additional benefit and does not affect your statutory rights.
Draper Tools Limited.

4

Summary of Contents for 32284

Page 1: ...ty together with longer life of the product itself All photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the product Whilst every effort has been made to ensure the accuracy of information contained in this manual the Draper Tools policy of continuous improvement determines the right to make modifications without prior warning IMPORTANT PLEASE...

Page 2: ...F UK 1 3 UNDERSTANDING THIS MANUALS SAFETY CONTENT WARNING Information that draws attention to the risk of injury or death CAUTION Information that draws attention to the risk of damage to the product or surroundings 1 4 COPYRIGHT NOTICE Copyright Draper Tools Limited Permission is granted to reproduce this publication for personal educational use only Commercial copying redistribution hiring or l...

Page 3: ...REPARING THE HEATER 8 1 HANDLE FITMENT 11 8 2 HANDLE WHEEL FITMENT 11 8 3 WHEELS 11 8 4 FUELS 12 8 5 FUELLING YOUR HEATER 12 8 6 VENTILATION 12 9 OPERATING THE HEATER 9 1 TO START HEATER 13 9 2 TO SHUT DOWN HEATER 13 9 3 TO RESTART HEATER 13 9 4 FUEL SYSTEM 13 9 5 THE SAFETY SYSTEM 13 9 6 STORING TRANSPORTING OR SHIPPING 14 9 7 DRAINING THE FUEL TANK 14 10 MAINTENANCE 10 1 FUEL TANK 15 10 2 AIR IN...

Page 4: ... hired out when the guarantee period is 90 days from the date of purchase The guarantee is extended to 24 months for parts only This guarantee does not apply to normal wear and tear nor does it cover any damage caused by misuse careless or unsafe handling alterations accidents or repairs attempted or made by any personnel other than the authorised Draper warranty repair agent Note If the tool is f...

Page 5: ...nsions 1050x445x540mm 890x405x510mm 1030x430x550mm Stock no 32286 53926 32287 Part no DSH750 DSH751 DSH450 Motor Rated voltage 230V 230V 230V Rated frequency 50Hz 50Hz 50Hz Rated input 300W 300W 300W Heat output 75 000 BTU 22kW 75 000 BTU 22kW 45 000 BTU 13kW Air flow 399m3 Hr 399m3 Hr 205m3 Hr Fuel Diesel Kerosene Diesel Kerosene Diesel Kerosene Diesel consumption 2 1Ltrs hr 2 1Ltrs hr 1 3Ltrs hr...

Page 6: ...ent such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Prevent unintentional starting Ensure the switch is in the off position before connecting to power source d Remove any adjusting key or wrench before turning the heater on A wrench or a key left attached to a rotating part of the heater may result in personal i...

Page 7: ...ng Early signs of carbon monoxide poisoning resemble flu like symptoms such as headaches dizziness and or nausea If you have these symptoms your heater may not be working properly Get fresh air at once Have the heater serviced Some people are more affected by carbon monoxide than others These include pregnant women those with heart or lung problems anaemia or those under the influence of alcohol o...

Page 8: ...g a replacement must be obtained or the plug replaced with a suitable type If a replacement plug is to be fitted this must be carried out by a qualified electrician The damaged or incomplete plug when cut from the cable shall be disabled to prevent connection to a live electrical outlet This appliance is Class I and is designed for connection to a power supply matching that detailed on the rating ...

Page 9: ...et Handle front Digital Temp display Handle rear Fan guard Fuel tank Drain plug Power cable Power switch Thermostat control Indicator lamp Fuel cap Fuel Gauge Leg frame Bracket Fixing kit Axle Wheels Wheel fixing kit Handle fixing kit Wheel and frame Kit not supplied with 32286 or 32287 9 ...

Page 10: ...Draper Helpline the telephone number appears on the Title page and do not attempt to use the product The packaging material should be retained at least during the guarantee period in case the heater needs to be returned for repair Warning Some of the packaging materials used may be harmful to children Do not leave any of these materials in the reach of children If any of the packaging is to be thr...

Page 11: ...ure with the split pin NOTE Bend the ends of the pin to prevent it from falling out during use iv Align the heater on the leg frame NOTE Air inlet over the wheels v Align the front and rear handles vi With four of the bolts and nuts provided sandwich the upper handle fuel tank lip and leg frame The remaining four bolts and nuts attach the handles to the fuel tank lip only 8 3 WHEELS 32284 53925 i ...

Page 12: ...ners or other oil compounds in this heater THESE ARE VOLATILE FUELS THAT CAN CAUSE A FIRE OR EXPLOSION NEVER store kerosene in direct sunlight or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER 8 5 FUELLING YOUR HEATER Never fill the heater fuel tank in the living space fill...

Page 13: ... passes in front of the fuel intake it causes fuel to rise from the tank and into the burner nozzle This fuel and air mixture is then sprayed into the combustion chamber in a fine mist The electronic ignitor sends voltage to a specially designed spark plug The spark plug ignites the fuel and air mixture described The heavy duty motor turns a fan that forces air into and around the combustion chamb...

Page 14: ... debris is noted in old fuel add 1 or 2 litres of clean fuel into tank wash around and drain again This will prevent excess debris from clogging the filters during future use Replace fuel cap and drain plug Properly dispose of old and dirty fuel in line with local disposal regulations DO NOT dispose of old fuel into a main drains this is illegal Before storing drain the fuel tank empty and clean t...

Page 15: ...TER FIG 5 REPLACE EVERY 500 HOURS OF OPERATION OR ONCE A YEAR Remove upper shell and fan guard Remove end filter cover screws using No 2 cross slot screwdriver Remove end filter cover Replace air output and lint filter Reinstall end filter cover Reinstall fan guard and upper shell 10 4 FAN BLADES CLEAN EVERY SEASON OR AS NEEDED Remove upper shell See Air Intake Filter Use M6 hex key to loosen set ...

Page 16: ...e cover Replace fan and upper shell 10 6 FUEL FILTER FIG 10 CLEAN OR REPLACE TWICE PER HEATING SEASON OR AS NEEDED Remove side cover screws using No 2 cross slot screwdriver Remove side cover and disconnect wires as necessary Pull fuel line off fuel filter neck Turn fuel filter anticlockwise 90 degrees pull and remove Wash fuel filter with clean fuel and replace in tank Attach fuel line to fuel fi...

Page 17: ... Turn the nozzle rod clockwise to reassemble into the burner head Attach ignitor wire to spark plug Attach fuel and air line hoses to burner head Reinstall fan blade and upper shell 10 8 SPARK PLUG FIG 13 CLEAN AND RE GAP EVERY 600 HOURS OF OPERATION OR REPLACE AS NEEDED Remove upper shell See Air Intake Filter Remove fan See Fan Blades Remove ignitor wire from spark plug Remove spark plug from bu...

Page 18: ...Clean photocell lens with cotton swab TO REPLACE Remove side Cover near power switch Disconnect wires from circuit board and remove photocell Install new photocell and attach wires to circuit board Reinstall fan and upper shell For models 32285 32274 only Remove upper shell See Air Intake Filter page 8 Remove fan See Fan Blades Remove photocell from its mounting bracket Clean photocell lens with c...

Page 19: ...al authority for details of collection schemes in your area In all circumstances Do not dispose of power tools with domestic waste Do not incinerate Do not abandon in the environment Do not dispose of WEEE as unsorted municipal waste Waste Electrical Electronic Equipment 12 EXPLANATION OF SYMBOLS WEEE Do not dispose of Waste Electrical Electronic Equipment in with domestic rubbish 19 ...

Page 20: ... U K Helpline 023 8049 4344 Sales Desk 023 8049 4333 General Enquiries 023 8026 6355 Service Warranty Repair Agent For aftersales servicing or warranty repairs please contact the Draper Tools Helpline for details of an agent in your local area YOUR DRAPER STOCKIST PJKC0616 drapertools com ...