10. MAINTENANCE
WARNING: Never service heater while it is plugged in or while
hot!
USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of
third-party or other alternate components will void warranty
and may cause unsafe operating conditions.
10.1 FUEL TANK
Flush every 200 hours of operation or as needed.
10.2 AIR INTAKE FILTER - FIG. 4
WASH AND DRY WITH SOAP AND WATER EVERY 500 HOURS
OF OPERATION, OR AS NEEDED.
-
Remove screws along side of heater using No.2 cross slot
screwdriver.
-
Lift off upper shell.
-
Remove fan guard.
-
Wash or replace air intake filter.
-
Reinstall fan guard and upper shell
10.3 AIR OUTPUT FILTER, LINT FILTER - FIG. 5
REPLACE EVERY 500 HOURS OF OPERATION OR ONCE A YEAR
-
Remove upper shell and fan guard.
-
Remove end filter cover screws using No.2 cross slot
screwdriver.
-
Remove end filter cover
-
Replace air output and lint filter
-
Reinstall end filter cover.
-
Reinstall fan guard and upper shell
10.4 FAN BLADES
CLEAN EVERY SEASON OR AS NEEDED
-
Remove upper shell (See Air Intake Filter).
-
Use M6 hex. key to loosen set screw which holds fan blade
to motor shaft.
-
Slip fan blade off motor shaft.
-
Clean fan blade using soft cloth moistened with water and
a mild detergent.
-
Dry fan blade thoroughly.
-
Reinstall fan blade to motor shaft.
-
Place fan blade hub flush with end of motor shaft.
-
Place set screw on flat of shaft.
Air intake
Filter
Fan Guard
Air Output Filter
Intake
Filter
End Filter
Cover
Lint Filter
Upper Shell
FIG.4
FIG.5
15