– 14 –
To select whether off timer mode is operated or not. At that time, off timer lamp displays)
Set Temp. / Time indicates the reserved time.
By pushing ‘+/_’ button, time is changed every an hour. It can be set in 24 hours totally.
Set Temp. or Set Time indicates again after 2 seconds
Remain time indicates by flickering 10 times every 5 min.
Off Timer is indicated when set the off timer for 5 hours. (5, 4, 3hr …….55, 50…5min)
During the operation if you push Off Timer button, Off timer function is cancelled.
Low fuel warning light
Heater will turn off in one minute. Once heater has cooled, switch off and refuel as necessary.
Service light
If service light is showing – refer to Troubleshooting Guide – 13.1.
9.3 HOW TO BLEED FUEL LINES
If you notice that the fuel pump is noisy and the heater is not igniting it is most likely that air has
entered the fuel pipes due to the heater being operated without fuel.
It is simple to bleed the air out of the fuel line.
Simply open the access cover on the front of the heater and remove the rubber bung to expose
the fuel bleed screw.
Release the bleed screw anti-clockwise for 2-3 turns.
press the on button to operate the pump unit and after around 10 seconds you will see the air
bleed out of the fuel line.
Tighten the screw and operate the heater as normal.
Depending on how much air has been sucked into the heater, you may need to bleed the fuel line
in this manner up to 4 times.
9. OPERATING THE HEATER