DranTech X
TRA
User’s Guide
37
V/Hz,
Ω
, Temperature,
and A/Hz Measurements
5.5
Temperature Measurement
Temperature measurement is performed with a type K thermocouple
(accessory not included), which is connected to the voltage input. Al-
ternatively, a Pt100 or Pt1000 resistance thermometer can be used
with the DranTech X
TRA
.
Selecting the Unit of Measure for Temperature
1nFo
Z
...
Z
tEMP
°C / °F
UV
(
°C
= default setting)
5.5.1 Measurement with Thermocouples, Temp TC
∞
Set the rotary switch to “Temp
TC
”.
Note!
The last selected temperature measurement or the last selected
temperature sensor, i.e. type K or Pt100/Pt1000, remains in
memory and is accordingly displayed. Press the
FUNC |
ENTER
key in order to change to the other measuring function
if required.
∞
The reference temperature is measured at the internal
reference junction (see parameter “1tEMP ” in chapter 6.3 regarding
querying).
Note!
The internal reference temperature (temperature of the internal
reference junction) is measured by a temperature sensor inside
of the instrument. This may be somewhat above room tempera-
ture as a result of internal heat-up, or moving from warmer to
colder surroundings or vice versa.
∞
Connect the sensor to the two accessible jacks. The instrument dis-
plays the measured temperature using the selected unit of measure.
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
Temp
TC
0023.3
°Χ
Temp
RTD
Type K
TC
COM
V
Temp
Ω
TE (TC)
0256.0
°Χ
Pt1000
RTD
Measuring Range
TE (TC)
K (NiCr-Ni)
–250.0
…
+1372.0
°
C
FUNC
ENTER
Summary of Contents for DranTech Xtra
Page 1: ...DranTech XTRA TRMS Digital Multimeter User s Guide P N M240H 2007 Rev A...
Page 5: ...DranTech XTRA User s Guide 5 Contact Persons...
Page 11: ...DranTech XTRA User s Guide 11 Safety Precautions...
Page 25: ...DranTech XTRA User s Guide 25 Control Functions...
Page 43: ...DranTech XTRA User s Guide 43 V Hz Temperature and A Hz Measurements...
Page 49: ...DranTech XTRA User s Guide 49 Device and Measuring Parameters...