background image

Dramm Turbo ULV Manual Supplement 9/18 

 

Mixing Instructions: 

 

The Turbo ULV requires the use of a carrier solution for best application.  The carrier solution helps to 

produce a more even sized droplet, preventing very large droplets from forming. 

 

While some chemicals may include fogging adjuvants, most do not.  Check with your chemical 

manufacturer regarding this. 

 

Dramm sells three different carrier solutions for the pulsFOG: VK-I, VK-II and NutriFOG. 
 

 

 

VK-I

   

Use with EC chemicals only 

 

 

VK-II

   

Use with all formulations of chemical 

 

 

NutriFOG

 

Use with all formulations of chemical 

 

VK-I

 requires no water for mixing.  Mix the correct quantity (see accompanying chart) of EC chemical 

directly into 1 liter of VK-I to treat 10,000 square feet. 

 

NOTE: Do not apply VK-I over wet crops.  Leaves should be dry during the application

 

VK-II

 is mixed with water.  Mix the correct quantity (see accompanying chart) of chemical with 0.5L of 

VK-II and 1.5 L of water to treat 10,000 square feet. 

 

NOTE: VK-II can damage certain crops, especially when in bloom.  Take care when using, 

especially later in the season. 

 

NutriFOG

 is mixed with water.  Mix the correct quantity (see chart) of chemical with 0.25 L of 

NutriFOG and 1.75 L of water to treat 10,000 square feet.  

 

NOTE: Do not apply more that 1.5 L of NutriFOG to the same 10,000 square foot area in ONE 

MONTH. 

 

While these carrier solutions have been used with most greenhouse chemicals without incident, it is 

always advisable to perform a jar test with the proper ratios of chemical, carrier, and water to ensure 

compatibility with any chemical you are not certain of. 

 

 

 
 

 

 

 

 

 

 

 

Summary of Contents for pulsFOG Turbo

Page 1: ...Dramm Turbo ULV Manual Supplement 9 18 Supplemental Manual for Turbo ULV Hybrid Sprayer...

Page 2: ...and care for your pulsFOG Turbo ULV Hybrid The included pulsFOG manual handles basic operation of your unit In addition to these manuals advice and operational videos are available on our website at...

Page 3: ...t the opinion of experts and are believed to be reliable Special emphases should be paid to dilution rates temperatures and application rates of pesticides as listed on their labels It further warrant...

Page 4: ...r of VK I to treat 10 000 square feet NOTE Do not apply VK I over wet crops Leaves should be dry during the application VK II is mixed with water Mix the correct quantity see accompanying chart of che...

Page 5: ...FIRST Calculate the amount of chemical required for 10 000 square feet Find the 100 gallon chemical label rate for the product you wish to apply Multiply this by 0 40 This is the amount of chemical to...

Page 6: ...The chart on the following page describes how to mix carrier solutions as well as converts chemical rates at the 0 40 rate NEXT Determine the amount of spray solution to use for your application Ultr...

Page 7: ...0 ounces 3 6 ounces 10 0 ounces 4 0 ounces 11 0 ounces 4 4 ounces 12 0 ounces 4 8 ounces 13 0 ounces 5 2 ounces 14 0 ounces 5 6 ounces 15 0 ounces 6 0 ounces 16 0 ounces 6 4 ounces 17 0 ounces 6 8 ou...

Page 8: ...l with 0 5 Liters of warm water and fog through the machine to clean out the solution lines After five hours of use inspect the air filters in the rear of the housing for wear or clogging Replace if n...