background image

Dramm Turbo ULV Manual Supplement 9/18 

 

Mix with the appropriate amount of carrier and water for 15,000 square feet.  Adjust the carrier and 

water based on the same ratio above. 

 

NOTE

: If the chemical you are using provides an area rate on the label in addition to the 100 gallon 

rate, 

USE THIS INSTEAD OF CALCULATING

 as shown above. 

 

Example: 

The label states “Use 10 oz per acre of CHEMICAL Z.” 

One acre is 43,560 square feet. 

Divide 10 oz/43,560 sq ft (to determine how much per sq ft.) = 0.00023 oz/sq ft. 

Multiply by the number of sq ft to be covered. 0.00023 x 15,000 sq ft = 3.4 oz 

 

Mix into the appropriate amount of carrier and water for 15,000 square feet.  Adjust the carrier and 

water based on the previous example. 

 

The chart on the following page describes how to mix carrier solutions as well as converts chemical 

rates at the 0.40 rate. 

 

NEXT: Determine the amount of spray solution to use for your application: 

 

Ultra Low Volume (space treatment) Application  

 

The Turbo ULV has a tank capacity of 5 liters. Up to a maximum of 25,000 square feet can be treated 

with the Turbo ULV using the ULV method. 

 

Under this method, use 

1 liter of FINISHED SOLUTION to treat 5,000 square feet.

 Mixing instructions 

for solution are described in a chart on the following page. 

 

Targeted Low Volume (directed treatment) Application  

 
The Turbo ULV has a tank capacity of 5 liters. Up to a maximum of 5,000 square feet can be treated 

with the Turbo ULV using the Targeted Low Volume method. 

 

Under this method, use 

1 liter of FINISHED SOLUTION to treat 1,000 square feet.

 Mixing instructions 

for solution are described in a chart on the following page. 

 

Summary of Contents for pulsFOG Turbo

Page 1: ...Dramm Turbo ULV Manual Supplement 9 18 Supplemental Manual for Turbo ULV Hybrid Sprayer...

Page 2: ...and care for your pulsFOG Turbo ULV Hybrid The included pulsFOG manual handles basic operation of your unit In addition to these manuals advice and operational videos are available on our website at...

Page 3: ...t the opinion of experts and are believed to be reliable Special emphases should be paid to dilution rates temperatures and application rates of pesticides as listed on their labels It further warrant...

Page 4: ...r of VK I to treat 10 000 square feet NOTE Do not apply VK I over wet crops Leaves should be dry during the application VK II is mixed with water Mix the correct quantity see accompanying chart of che...

Page 5: ...FIRST Calculate the amount of chemical required for 10 000 square feet Find the 100 gallon chemical label rate for the product you wish to apply Multiply this by 0 40 This is the amount of chemical to...

Page 6: ...The chart on the following page describes how to mix carrier solutions as well as converts chemical rates at the 0 40 rate NEXT Determine the amount of spray solution to use for your application Ultr...

Page 7: ...0 ounces 3 6 ounces 10 0 ounces 4 0 ounces 11 0 ounces 4 4 ounces 12 0 ounces 4 8 ounces 13 0 ounces 5 2 ounces 14 0 ounces 5 6 ounces 15 0 ounces 6 0 ounces 16 0 ounces 6 4 ounces 17 0 ounces 6 8 ou...

Page 8: ...l with 0 5 Liters of warm water and fog through the machine to clean out the solution lines After five hours of use inspect the air filters in the rear of the housing for wear or clogging Replace if n...