54
Finalizing the Installation
(for qualified installers only)
Travis Industries
4101014
100-01257_000
6
Follow the directions below to replace the orifices.
Look here for the orifice identification
Apply thread sealant to the LP
orifices prior to installation. Use
the chart below to identify the
correct orifices.
Center
Sides
NG
#53
#60
LP
#63
#70
Screw each LP orifice in so the
orifice protrudes 15/16" (24mm)
(indicating full insertion).
d
15/16"
24mm
c
1/2" Wrench
Use a 1/2" open end wrench
to unscrew the three orifices.
b
Remove the three air shutters
(they rotate away from the
orifices and slide out).
a
Right Side Orifice
Left Side Orifice
Center Orifice