PROPRIETARY AND CONFIDENTIAL DRAFT 5 Feb 04
2 - 21
GAS USAGE EFFICIENCY
Duration of Gas Supply
Time per liter of cylinder volume
Example for E cylinder
Typical Cylinder Pressure
2200 psi nominal
ENVIRONMENTAL
Operating Temperature Range
18 °C to 30 °C (64.4 °F to 86 °F) ambient
Operating Relative Humidity Range
5% RH to 95% RH, non-condensing
Operating Altitude Range
up to1.8 km (up to 6000')
Storage/Transport Temperature Range
- 20 °C to + 60 °C (-4 °F to + 140 °F) ambient
Storage/Transport Relative Humidity Range
5% RH to 95% RH, non-condensing
Storage/Transport Altitude Range
up to12 km (up to 40000')
ACOUSTICS
Measuring device located 3 m (9.8”) in front of
device and 1.5 m (70.9”) above device
Acoustical Level (no alarms on)
60 dBa maximum
Acoustical Level (all alarms on)
75 dBa maximum
Acoustical Level (measuring device on the
mattress)
80 dBa maximum
DEVICE CLASSIFICATION
Protection Class (IEC60601-1)
Class I, type BF
Ingress of Liquids and Particulate Matter
(IEC60601-1)
IPX0
Classification in accordance with EU Directive
93/42/EEC Appendix IX
Device class IIb
UMDNS Code/GMDN Code
13-250/17956
EXPECTED SERVICE LIFE
7 years
Feature
Dimension
psi cylinderfactor
×
LPM
----------------------------------------------------
min
60
---------
hours
=
=
2200 0.28
×
5
----------------------------
123.2
60
-------------
2
hours
5
min
=
=