Table 3 - Troubleshooting
Symptom
Fault
Remedy
Face mask air leak
O-ring at LDR to facepiece connection
Headstraps not tight
Exhalation valve leaking
Speech diaphragm defective
Renew or lubricate O-ring
Tighten
Maintenance task
Maintenance task
Unsatisfactory communication
Speech diaphragm defective
Maintenance task
High-pressure air leak
Loose connections
Faulty or missing hose seals
Maintenance task
Maintenance task
Safety relief valve venting
First-stage regulator defective
Maintenance task
LDR allowing constant air flow into the
fask mask
Bypass button engaged
Internal fault
Turn off the bypass button (3, Fig 13)
Maintenance task
Whistle not sounding correctly
Whistle dirty or faulty
Maintenance task
Whistle sounding continuously
Damaged sealing on HP capillary
Defective activation mechanism
Maintenance task
Maintenance task
Low battery indication on the user
interface (Fig 4)
Low main battery
Renew the main battery
Fault code indication on the user
interface (Fig 12)
Sentinel 7000 failure
Maintenance task
Sentinel 7000 will not switch on
Low main battery
Low cylinder pressure (below 145psi)
Unknown
Renew the main battery
Recharge cylinder to maximum working pressure
Maintenance task
HUD battery LED flashing green
Low battery - HUD
Renew the HUD battery
HUD battery LED flashing yellow
Low main battery
Renew the main battery
HUD will not log on to the Sentinel
7000
HUD not close enough
Low HUD battery
Low cylinder pressure (below 100 psi)
Unknown
Move the HUD to within three feet of the pressure
module
Renew the HUD battery
Recharge cylinder to maximum working pressure
Maintenance task