Collagen exposure program

•  Photosensitive persons (e.g. LE or MCS) 

should consult a physician before use.

•  Please  note:  certain  medication  can  infl u-

ence  the  body's  general  reaction  to  light. 
Please consult your physician in case of any 
doubt. 

•  If  you  notice  any  uncomfortable  skin  re-

actions during or after use, stop using the 
unit  immediately  and  seek  advice  from  a 
dermatologist. 

 Exposure distance

The exposure distance is specifi ed by the 
construction of the unit and may never be 
reduced. For standing units, the exposure 
distance is provided separately in the "ope-
rating" chapter.

The recommended period of use is 20 mi-
nutes, 2-3 times per week.

Important notes on the use of col-
lagen

Read the instructions carefully.

When using a collagen unit, it is necessary 
that possible overreactions of the skin are 
carefully observed and the following advice 
is precisely followed.

Please consult a physician before use if 
the below points apply to you.

•  Persons who suffer from sunburn;

•  Persons with more than 20 moles on their 

bodies;

•  Persons  who  have  unusual  moles  - 

consult a physician in case of any dou-
bt;

•  Persons with unusual discolored areas of 

skin;

•  Persons  who  suffer,  or  have  suffered 

from  skin  cancer  or  persons  who  are 
predisposed to this;

•  Persons  whose  close  relatives  have 

been diagnosed with skin cancer;

•  Always use the protective eyewear provi-

ded.  Contact  lenses  and  sunglasses  are 
not  an  alternative  for  the  protective  eye-
wear;

•   Remove any cosmetics before exposu-

re  and  do  not  use  any  sun  protection 
lotions or acceleration products;

•  Certain  medical  conditions  or  side-

effects  from  medication  can  be  rein-
forced by  exposure; ask physician for 
advice in case of any doubt;

•  Please allow at least 48 hours to elapse 

before another exposure session takes 
place.

After exposure

Use a moisturizing lotion after the session to 
care for your skin. This will keep the appea-
rance of your skin fresh.

Summary of Contents for Skinfresh Tancan 3000

Page 1: ...1 D IP20 Skinfresh Tancan 3000 Druck Nr 29494042en 15 11 GB Assembly and operating instruction...

Page 2: ...or element 9 7 Electrical connection of the elements 10 8 Installing the upper trim panels 10 9 Installation of main connection cable cover panel 10 Operation 12 Timer adjustment 12 Operation via exte...

Page 3: ...ocess is mainly responsible for the development of collagen and elastin and provides a more taut youthful and fresh complexion The penetrability of the skin for cosmetic products is also increased so...

Page 4: ...ted physical sensory or mental capacity or by persons without the ne cessary experience and or knowledge unless they are supervised by some one responsible for their safety or re ceive instructions fr...

Page 5: ...dvice is precisely followed Please consult a physician before use if the below points apply to you Persons who suffer from sunburn Persons with more than 20 moles on their bodies Persons who have unus...

Page 6: ...electrician in keeping with national and local regulations 1 Baseplate Begin the assembly by removing the base plate D from package 4 and placing it at the intended location of the system Note The ba...

Page 7: ...2 take 2 distance col lars 9 two M10 nuts 10 and 2 lock was hers 11 and assemble as shown in Fig 5 Note The bearing 12 for the door element is already fitted in stand foot 8 9 12 10 11 8 Fig 5 Fig 6 1...

Page 8: ...ock washers 6 from the accessory pack M10 bolts 16 are provided in the upper sec tions of both elements Place the installation plate with its holes over the bolts 16 and fix it firmly in place using t...

Page 9: ...the castor 22 onto the retaining bolt 21 Fig 16 Lift the door element 20 with the pre assem bled bearing bolt 23 onto the installation plate 12 and slide the bearing into place fig 17 To assemble the...

Page 10: ...of the system Fig 20 using for each panel two self tapping screws 34 on the outside and two M4 screws in the central area Ensure that a distance sleeve is placed bet ween the trim panel and rear wall...

Page 11: ...11 GB Fig 23 Fig 22 37 36 37 Connect the main power cable to the mains power source using a fixed connection or a plug connection CECON plug The system is now ready for operation 35 Fig 21...

Page 12: ...gram Timer adjustment Jumper left side fan delay opened without fan delay closed with fan delay Fig 25 Operation The unit will be switched on by using the On Off switch 1 at the digital timer With the...

Page 13: ...latine Segment 1 Segment 2 Segment 3 Hauptanschlu M nzanschlu rechts right T r door links left K rperl fter K rperl fter L Zeit N 4 N PE 1 2 3 L1 L2 N PE 4 2 1 3 PE L3 N 1 2 3 4 L1 N Zeit 3 5 4 SD PE...

Page 14: ...site edge locks into place on the other edge of the mounting frame Fig 28 Replacing tubes and starters To replace tubes and starters first remove the acrylic plates as described above The tubes in you...

Page 15: ...line confi guration exhaust hoses can be as long as 2 m without the need for an additional blower unit If the exhaust line is longer than 2 m or has bends the addition of an auxiliary blo wer unit is...

Page 16: ...he coin box the time will start counting from 0 minutes up wards The sun bed can be turned on or off within this time The up and down buttons are locked the other buttons remain functional The pre set...

Page 17: ...the equipment in its original packaging or other suitable pa ckaging caution danger of transport damage to our service department Always include the completed warrenty certifica te when returning equi...

Page 18: ...for the cheapest return Please pay attention that the goods have to be sent back without visible marks of use in the original scope of delivery and in original packing We recommend to use an addition...

Reviews: