Dr. Kern Skinfresh Tancan 3000 Assembly And Operating Instruction Download Page 10

10

GB

Now let the installation plate (24) drop down 
over the upper bearing, and tighten the two 
nuts (26) fi rmly (Fig. 18).

Fig. 18

7.  Electrical  connection  of  the  ele-

ments

All 3 elements have their electrical connec-
tions  at  the  top,  and  are  connected  to  the 
control unit (29) by means of the 3 plugs (30 
- 32) (Fig. 19).

Fig. 19

29 = Control unit
30 = Connection cable, right element
31 = Connection cable, left element
32 = Connection cable, door element
35 = Main connection cable

8. Installing the upper trim panels

Finally, fi t the three trim panels (33) around 
the upper edge of the system (Fig. 20), using 
for each panel two self-tapping screws (34) 
on  the  outside,  and  two  M4  screws  in  the 
central area.

Ensure that a distance sleeve is placed bet-
ween the trim panel and rear wall of the unit 
at each attachment point.

Fig. 20

9. Installation of main connection ca-
ble / cover panel

The  main  connection  cable  (35)  is  pre-as-
sembled  to  the  control  unit  (29),  and  lies 
rolled up on the exhaust unit.

Take the cable (35) and lead it down along 
the side of the system (Fig. 21).

Now  remove  the  cover  panel  (37)  from  pa-
ckage 3, and fi t it as shown in Fig. 22.

Note: 

The  existing  screws  in  the  rear 

walls  are  used  for  the  attachment  of 
the  cover  panel  (37).  These  screws 
must be removed before fi tting the co-
ver panel. 

25

24

26

27

28

29

30

31

32

35

33

34

Summary of Contents for Skinfresh Tancan 3000

Page 1: ...1 D IP20 Skinfresh Tancan 3000 Druck Nr 29494042en 15 11 GB Assembly and operating instruction...

Page 2: ...or element 9 7 Electrical connection of the elements 10 8 Installing the upper trim panels 10 9 Installation of main connection cable cover panel 10 Operation 12 Timer adjustment 12 Operation via exte...

Page 3: ...ocess is mainly responsible for the development of collagen and elastin and provides a more taut youthful and fresh complexion The penetrability of the skin for cosmetic products is also increased so...

Page 4: ...ted physical sensory or mental capacity or by persons without the ne cessary experience and or knowledge unless they are supervised by some one responsible for their safety or re ceive instructions fr...

Page 5: ...dvice is precisely followed Please consult a physician before use if the below points apply to you Persons who suffer from sunburn Persons with more than 20 moles on their bodies Persons who have unus...

Page 6: ...electrician in keeping with national and local regulations 1 Baseplate Begin the assembly by removing the base plate D from package 4 and placing it at the intended location of the system Note The ba...

Page 7: ...2 take 2 distance col lars 9 two M10 nuts 10 and 2 lock was hers 11 and assemble as shown in Fig 5 Note The bearing 12 for the door element is already fitted in stand foot 8 9 12 10 11 8 Fig 5 Fig 6 1...

Page 8: ...ock washers 6 from the accessory pack M10 bolts 16 are provided in the upper sec tions of both elements Place the installation plate with its holes over the bolts 16 and fix it firmly in place using t...

Page 9: ...the castor 22 onto the retaining bolt 21 Fig 16 Lift the door element 20 with the pre assem bled bearing bolt 23 onto the installation plate 12 and slide the bearing into place fig 17 To assemble the...

Page 10: ...of the system Fig 20 using for each panel two self tapping screws 34 on the outside and two M4 screws in the central area Ensure that a distance sleeve is placed bet ween the trim panel and rear wall...

Page 11: ...11 GB Fig 23 Fig 22 37 36 37 Connect the main power cable to the mains power source using a fixed connection or a plug connection CECON plug The system is now ready for operation 35 Fig 21...

Page 12: ...gram Timer adjustment Jumper left side fan delay opened without fan delay closed with fan delay Fig 25 Operation The unit will be switched on by using the On Off switch 1 at the digital timer With the...

Page 13: ...latine Segment 1 Segment 2 Segment 3 Hauptanschlu M nzanschlu rechts right T r door links left K rperl fter K rperl fter L Zeit N 4 N PE 1 2 3 L1 L2 N PE 4 2 1 3 PE L3 N 1 2 3 4 L1 N Zeit 3 5 4 SD PE...

Page 14: ...site edge locks into place on the other edge of the mounting frame Fig 28 Replacing tubes and starters To replace tubes and starters first remove the acrylic plates as described above The tubes in you...

Page 15: ...line confi guration exhaust hoses can be as long as 2 m without the need for an additional blower unit If the exhaust line is longer than 2 m or has bends the addition of an auxiliary blo wer unit is...

Page 16: ...he coin box the time will start counting from 0 minutes up wards The sun bed can be turned on or off within this time The up and down buttons are locked the other buttons remain functional The pre set...

Page 17: ...the equipment in its original packaging or other suitable pa ckaging caution danger of transport damage to our service department Always include the completed warrenty certifica te when returning equi...

Page 18: ...for the cheapest return Please pay attention that the goods have to be sent back without visible marks of use in the original scope of delivery and in original packing We recommend to use an addition...

Reviews: