Timer adjustment

Jumper, left side

Switching to coin box operation

2 persons are required for this procedure.

•  When the coin box is not connected yet, 

separate the sun bed completely from the 
power supply.

•  While  one  person  keeps  the  [up]  and 

[down] buttons at the timer control panel 
simultaneously pressed, the other person 
shall  connect  the  sun  bed  to  the  power 
supply.

•  When the coin box is already connected, 

the  sun  bed  must  not  be  disconnected 
from the power supply.

 

In this case proceed as follows:

 

one  person  keeps  the  [up]  and  [down] 
buttons at the timer control panel simulta-
neously pressed.

 

- the other person shall start the coin box 
running by throwing in a coin (token).

•  Keep pressing the [up] and [down] buttons 

until “0” appears on the timer display.

The sun bed is now coin box operated.
After  being  released  by  the  coin  box  the 
time will start counting from “0” minutes up-
wards.
The sun bed can be turned on or off within 
this time.
The [up] and [down] buttons are locked, the 
other buttons remain functional.
The  pre-set  time  has  elapsed,  the  sun  bed 
will be completely switched off and time dis-
play will go out. 

Attention:  The  fan  delay  has  to  be 

executed by the coin box!

 

Returning to timer operation

Returning the sun bed back to timer operati-
on is only possible if the coin box is comple-
tely disconnected and the jumper “L1-Time” 
is restored (see connection diagram). 

2 persons are required for this procedure.

•  Disconnect the sun bed completely from 

the power supply.

•  While  one  person  keeps  the  body  fan 

and  face  tanner  buttons  simultaneously 
pressed,  the  other  person  shall  connect 
the sun bed to the power supply again.

•  Keep pressing both buttons until “88” ap-

pears on the timer display.

•  The display will go out thereafter.

The sun bed is now timer operated.

Jumper, left side (fan delay)
opened = without fan delay
closed = with fan delay

Summary of Contents for Skinfresh Tancan 3000

Page 1: ...1 D IP20 Skinfresh Tancan 3000 Druck Nr 29494042en 15 11 GB Assembly and operating instruction...

Page 2: ...or element 9 7 Electrical connection of the elements 10 8 Installing the upper trim panels 10 9 Installation of main connection cable cover panel 10 Operation 12 Timer adjustment 12 Operation via exte...

Page 3: ...ocess is mainly responsible for the development of collagen and elastin and provides a more taut youthful and fresh complexion The penetrability of the skin for cosmetic products is also increased so...

Page 4: ...ted physical sensory or mental capacity or by persons without the ne cessary experience and or knowledge unless they are supervised by some one responsible for their safety or re ceive instructions fr...

Page 5: ...dvice is precisely followed Please consult a physician before use if the below points apply to you Persons who suffer from sunburn Persons with more than 20 moles on their bodies Persons who have unus...

Page 6: ...electrician in keeping with national and local regulations 1 Baseplate Begin the assembly by removing the base plate D from package 4 and placing it at the intended location of the system Note The ba...

Page 7: ...2 take 2 distance col lars 9 two M10 nuts 10 and 2 lock was hers 11 and assemble as shown in Fig 5 Note The bearing 12 for the door element is already fitted in stand foot 8 9 12 10 11 8 Fig 5 Fig 6 1...

Page 8: ...ock washers 6 from the accessory pack M10 bolts 16 are provided in the upper sec tions of both elements Place the installation plate with its holes over the bolts 16 and fix it firmly in place using t...

Page 9: ...the castor 22 onto the retaining bolt 21 Fig 16 Lift the door element 20 with the pre assem bled bearing bolt 23 onto the installation plate 12 and slide the bearing into place fig 17 To assemble the...

Page 10: ...of the system Fig 20 using for each panel two self tapping screws 34 on the outside and two M4 screws in the central area Ensure that a distance sleeve is placed bet ween the trim panel and rear wall...

Page 11: ...11 GB Fig 23 Fig 22 37 36 37 Connect the main power cable to the mains power source using a fixed connection or a plug connection CECON plug The system is now ready for operation 35 Fig 21...

Page 12: ...gram Timer adjustment Jumper left side fan delay opened without fan delay closed with fan delay Fig 25 Operation The unit will be switched on by using the On Off switch 1 at the digital timer With the...

Page 13: ...latine Segment 1 Segment 2 Segment 3 Hauptanschlu M nzanschlu rechts right T r door links left K rperl fter K rperl fter L Zeit N 4 N PE 1 2 3 L1 L2 N PE 4 2 1 3 PE L3 N 1 2 3 4 L1 N Zeit 3 5 4 SD PE...

Page 14: ...site edge locks into place on the other edge of the mounting frame Fig 28 Replacing tubes and starters To replace tubes and starters first remove the acrylic plates as described above The tubes in you...

Page 15: ...line confi guration exhaust hoses can be as long as 2 m without the need for an additional blower unit If the exhaust line is longer than 2 m or has bends the addition of an auxiliary blo wer unit is...

Page 16: ...he coin box the time will start counting from 0 minutes up wards The sun bed can be turned on or off within this time The up and down buttons are locked the other buttons remain functional The pre set...

Page 17: ...the equipment in its original packaging or other suitable pa ckaging caution danger of transport damage to our service department Always include the completed warrenty certifica te when returning equi...

Page 18: ...for the cheapest return Please pay attention that the goods have to be sent back without visible marks of use in the original scope of delivery and in original packing We recommend to use an addition...

Reviews: