background image

 

19 

 

Failure code

 

NO.  Display code 

Failure Description 

E3 

No water protection 

E5 

Power supply excesses operation range 

E6 

Excessive temp difference between inlet and outlet water 
(Insufficient water flow protection) 

Eb 

Ambient temperature too high or too low protection 

Ed 

Anti-freezing reminder 

NO.  Display code 

Failure description 

E1 

High pressure protection 

E2 

Low pressure protection 

E4 

3 phase sequence protection (three phase only) 

E7 

Water outlet temp too high or too low protection 

E8 

High exhaust temp protection 

EA 

Evaporator overheat protection (only at cooling mode) 

P0 

Controller communication failure 

P1 

Water inlet temp sensor failure 

P2 

Water outlet temp sensor failure 

10 

P3 

Gas exhaust temp sensor failure 

11 

P4 

Heating (Evaporator)coil pipe temp sensor failure 

12 

P5 

Gas return temp sensor failure 

13 

P6 

Cooling (Titanium heat exchanger) coil pipe temp sensor failure 

14 

P7 

Ambient temp sensor failure 

15 

P8 

Cooling plate sensor failure 

16 

P9 

Current sensor failure 

17 

PA 

Restart memory failure 

18 

F1 

Compressor drive module failure   

19 

F2 

PFC module failure 

20 

F3 

Compressor start failure 

21 

F4 

Compressor running failure 

22 

F5 

Inverter board over current protection 

23 

F6 

Inverter board overheat protection 

24 

F7 

Current protection 

25 

F8 

Cooling plate overheat protection 

26 

F9 

Fan motor failure 

27 

Fb 

Capacitor no-power protection 

28 

FA 

PFC module over current protection 

 

Summary of Contents for DR-1100HP

Page 1: ......

Page 2: ...ION 3 III FEATURES 4 IV ACCESSORY 4 V TECHNICAL PARAMETERS 5 VI DIMENSION 6 VII INSTALLATION INSTRUCTIONS 7 VIII OPERATION INSTRUCTIONS 13 IX STARTING 15 X MAINTENANCE 16 XI TROUBLESHOOTING 18 XII WI...

Page 3: ...al conditions such as noise smell smoke or electrical leakage please switch off the machine immediately and contact the local dealer Don t try to repair it by yourself 5 Don t use or stock combustible...

Page 4: ...ing the heat pump 1 This product is only for heating swimming pool or spa water It cannot be used for other applications 2 Inlet and outlet water nozzles are not designed to bear the weight of externa...

Page 5: ...the local dealer installer 11 Do not attempt to repair the heat pump yourself II Application 1 Set swimming pool water temp efficiently and economically to provide you comfort and pleasure 2 The user...

Page 6: ...o low or no water flow 4 Exceeding low temperature auto stop protection 5 Temperature control forced defrosting 6 International brand compressor 7 High efficient titanium heat exchanger 8 Easy install...

Page 7: ...ormance Condition Air 80 F 27 Water 80 F 27 Humidity 63 Heating capacity Btu 61 500 85 000 104 000 Heating capacity Btu in silence mode 49 200 68 000 83 500 C O P 9 9 5 35 12 3 5 7 12 2 5 6 Performanc...

Page 8: ...ithout notice A B C D E F G H DR 650HP 15 6 23 2 15 4 16 5 37 8 14 2 2 9 25 9 DR 900HP 15 6 28 3 15 4 16 5 43 0 24 4 2 9 37 7 A B C D E F G H DR 1100HP 36 3 17 6 35 6 37 2 27 8 20 9 3 3 38 5 BF E C H...

Page 9: ...in a sealed system ONLY trained and qualified service personnel are authorized to install or service this equipment Without proper training and knowledge of such equipment any attempt to install or s...

Page 10: ...e sensor for temperature automation control a Install wires from the automation controller for Heat on the terminal strip inside the heat pump s electrical compartment on the side of the heat pump b R...

Page 11: ...End users are not qualified to install the heat pump Damage may occur to the heather or threaten the safety of the user Notes 1 The inlet and outlet water unions of this machine can t support the weig...

Page 12: ...d to prevent re circulation of air We recommend not placing the unit underneath eaves decks or porches as this causes re circulation of discharged air thereby reducing the efficiency of the heat pump...

Page 13: ...11 the base Place the drainage nozzle into the condensation outlet and attach it securely then contact a drainage pipe from it to the drain DR 650HP DR 900HP DR 1100HP...

Page 14: ...l installation technician and follow the circuit diagram 4 Set leakage protection device according to the local code for wiring leakage action current 30mA specification 5 The layout of power cable an...

Page 15: ...en lock Only after screen is unlocked any other buttons can be functioning a If no button is used within 30 seconds the screen will lock automatically At this point the backlight will turn off and 0 w...

Page 16: ...press UP or DOWN to display or adjust the set temperature To change from Fahrenheit to Celsius press the UP and DOWM together for 5 seconds 3 Smart Silence mode selection Smart mode as default will be...

Page 17: ...5 Wi Fi setting Please kindly check the last page IX Starting A The user should start the pool pump and check for any leakage of water Power on and press the ON OFF button on the heat pump and set a s...

Page 18: ...Cold Weather Operation In the off season when the pool is not going to be used at all 1 Cut off the power supply to avoid damage to the heat pump 2 Drain water from the heat pump by removing the pipi...

Page 19: ...entire heat pump and pipe connections according to the pipe connecting drawing B Check the electric wiring according to the electric wiring diagram and grounding connection C Make sure that the main...

Page 20: ...e fuse Circuit breaker tripped Turn circuit breaker back on Heat pump runs but not heat Air inlet blocked Remove obstructions Air outlet blocked Remove obstructions 3 minute protection Please wait mor...

Page 21: ...er communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Heating Evaporator coil pipe temp sensor failure 12 P5 G...

Page 22: ...20 XII Wi Fi setting 1 APP Download Android mobile please download from iPhone please download from 2 Account registration a Registration by Cell phone number Email...

Page 23: ...21 b Cell phone number registration 3 Create a family account Please set a name for family and choose the room of device...

Page 24: ...phone b Press for 3 seconds after screen unlock will be flashing rapidly to enter Wi Fi binding status c Click Add Device wait for the app to search for the device and then click add then follow the...

Page 25: ...e flashing rapidly to enter Wi Fi binding status b Click Add device follow instructions below to finish binding display on the screen once Wi Fi connection success Note 1 After allowing the APP to loc...

Page 26: ...Click Add device follow instructions below to finish binding display on the screen once Wi Fi connection success Note If it doesn t jump automatically click Confirm hot spot connection next d If conn...

Page 27: ...nges or network configuration changes Press for 10 seconds will be flashing slowly for 60 seconds Then will be off The original binding will be removed Follow step above for rebinding Remarks Please m...

Page 28: ...are for heat pumps with heating function only More share device Indicate the status of Heating Compressor running percentage The current swimming pool water temp Setting temp Cloud Timer Switching C F...

Page 29: ...hare devices to your family members After binding if your family members also want to control the device Please let your family members register the APP first and then the administrator can operate as...

Page 30: ...28 Then your family members can log in as below Notice 1 The weather forecast is just for reference 2 APP is subject to updating without notice...

Page 31: ...ringing top quality alternative supplemental heating products to our customers How long is the warranty This heater comes with a THREE YEAR LIMITED COMPONENT WARRANTY If your unit does not appear to b...

Page 32: ...er pool heat pump The factory reserves the final interpretation right And keep the right to stop or change product specification and design without prior notice at any time no need to bear the resulti...

Reviews: