background image

 

19 

8.0 

Warranty 

 

Pursuant to our Terms & Conditions of Sale, we offer a warranty of 12 months from the date of purchase. 
This covers the free repair of material and production defects which are shown to have been caused prior 
to sale.  
 
An original sales receipt must always be produced when asserting a warranty claim. It must include the full 
address  of  the  dealer,  purchase  date,  and  type  code  of  the  product.  The  user  manual  for  the  relevant 
product as well as the safety instructions must have been followed. 
Damage caused by operating errors is not covered by the warranty. 
 
The  manufacturer’s  products  are  developed  and  built  for  specific  applications.  If  the  product  is  used  for 
purposes  other  than  the  intended  purpose  based  on  the  user  manual,  or  in  the  event  of  misuse,  or  if 
unapproved accessories are used, the warranty shall become null and void. 
 
The  products must  be  regularly maintained  and  cleaned  according to  the  instructions  in  the  user manual. 
The  warranty  shall  become  null  and  void  in  the  event  of  an  intervention  by  third  parties  (opening  the 
machine). 
The warranty does not cover maintenance and cleaning work. 
 
You must ensure that only original spare parts and accessories are used. The products must be purchased 
from  an  authorised  dealer.  If  non-original  parts  are  used,  this  may  result  in  consequential  damage  and 
increased  risk  of  accidents.  The  manufacturer  is  not  liable  for  such  damage.  Disassembled,  partially 
disassembled units, and units repaired with third party parts are not covered by the warranty. 
 
Certain  parts  are  subject  to  normal  wear  and  tear  depending  on  use.  These  parts  include  e.g.  carbon 
brushes, ball bearings, switches, mains cables, seals, etc. These consumable parts are not covered by the 
warranty. Consumable parts are highlighted in the spare parts lists. 

 

9.0 

General Safety Instructions 

 

The general safety instructions can be found in the supplied safety instruction booklet. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 102405

Page 1: ...PB RX SX 12 HF III Issued 05 2017 PB RX SX 12 Art no 102405 Subject to change Alle Rechte vorbehalten All rights reserved DR BENDER GmbH D 75382 Althengstett Tel 07051 9291 0 Fax 07051 9291 91 We are...

Page 2: ...2...

Page 3: ...w Voltage Directive 2006 95 EC The following harmonised standards have been used for assessment of the appliance EN 50144 1 EN 50144 2 1 EN 55014 1 EN 61000 3 2 EN 61000 3 3 EN 55014 2 EN 61029 1 Auth...

Page 4: ...0 4 3 Operating temperatures 10 5 0 Commissioning 11 5 1 Setting up 11 5 2 Mains connection 11 5 3 Powerbox water connection 11 5 4 Operating the Powerbox 12 5 5 Reversing the rotation of the motor 13...

Page 5: ...ich may endanger your health or the functionality of the unit if they are not followed The warranty shall become null and void if you cause defects to the unit by non compliance with these instruction...

Page 6: ...y signs on the machine Wear safety shoes Wear gloves Wear a safety helmet Wear protective goggles Wear ear protection Wear a breathing mask Pull the power plug before work on the device Read the instr...

Page 7: ...onnection 400 V 802267 Emergency stop button Speed control Mains connection 230 V 802343 Overload indicator LEDs Start button Stop button Water cooling Connection Motor Water cooling Air cooling Opera...

Page 8: ...come up against steel reinforcements and thus can be optimised according to the progress of the work Here you can run the unit at much higher cutting speeds Attention depends on the tool and in doing...

Page 9: ...C electromagnetic interference and interference resistance The allowed electromagnetic fields are still emitted Electromagnetic fields may interfere with the operation of critical electronic devices e...

Page 10: ...consumption 12 000 W Frequency 50 60 Hz Degree of protection IP 67 Cooling medium Air Water Weight 16 5 kg 4 3 Operating temperatures If the system is cooled by water the Powerbox attains the cooling...

Page 11: ...6 h Only use extension cables with earth conductors and of sufficient diameter If the diameter is too small this may lead to excessive power loss and to overheating of the motor and cable An extension...

Page 12: ...motor from accidentally restarting Green LED Green LED flashes standby Green LED lit machine on Switch the Powerbox to operating mode with the green start button on the Powerbox Green LED Green LED O...

Page 13: ...ime press the green start button for approx two seconds until all LEDs are lit on the Powerbox control panel Release the green and the red button again The rotation of the motor has been reversed Foll...

Page 14: ...14 5 7 Powerbox operating concept Power on Standby green 500 ms Box on ready green LED on Red button on box Motor connected Green button on box...

Page 15: ...15 5 8 Powerbox fault processing Wait for fault Shut off drive and stop control unit Red LED flashes Wait for green button on Powerbox or automatic reset Clear fault Jump to standby...

Page 16: ...he motor connectors for dirt and damage 2 Bring motor and box for repair F12 Earth leakage 1 Check the motor connectors for dirt and damage 2 Bring motor for repair F13 F14 Internal hardware fault 1 D...

Page 17: ...reason This prevents the unit from suddenly starting when unattended Do not use the unit when a part of the housing is missing or defective there is damage to switches lines or plug connections daily...

Page 18: ...ches the lines or the plug sockets Clean the units after completion of the work Check that no water gets into the units during cleaning Drain the cooling water after using the machine To do so hold th...

Page 19: ...products must be regularly maintained and cleaned according to the instructions in the user manual The warranty shall become null and void in the event of an intervention by third parties opening the...

Page 20: ...20 10 0 Spare parts lists 10 1 Powerbox PB RX SX 12...

Page 21: ...802467 PCB board 1 69 802316 Seal 1 18 802371 Plug connector 2 70 401712 Bushing 2 19 802742 PCB board 2 71 401713 Pin 2 20 401901 Insulation 1 72 802682 Panel plug 1 21 401900 Insulation 1 73 801147...

Reviews: