Specifications

Specifications for the MUX are shown below.

Dimensions

17.0"(W) X 12.0"(D) X 1.75"(H)

Mounting

The MUX can be mounted in a 19" or 23" rack.

The MUX unit can also be wall mounted.

Power Input -24 DC unit: -18 to -36 VDC @ 200 mA

-48 DC unit: -36 to -72 VDC @ 180 mA (max)
30 mA (typical).

Fuse

1/2 Amp

Operating Temperature Range

0 degrees to +60 degrees Celsius.

Humidity

0% to 95% non-condensing

Interface

1-RS232 (DB9) Craft Port on the front,
9 DB9 connectors on the back.

Buffers

16k byte on each MUX channel.

Electrical Interface:

Common Port: RS232
Eight Channel (source) Ports: RS232

Data Rates:

300, 1200, 2400 and 9600 Baud.

All specifications are subject to change without notice.

Options & Model Numbers

The ASCII MUX part numbers and options are listed below.

These options are constantly expanded. As a result, more op-
tions may be available than are listed below. Contact your dis-
tributor for currently available options.
D-PC-180-10A-02

ASCII MUX: RS 232, Wire-Wrap Connecions,
-24VDC.

D-PC-180-10A-04

ASCII MUX: RS 232, Wire-Wrap Connections
-48VDC.

D-PC-180-10A-12

ASCII MUX: RS 232, Connectorized, -24VDC.

D-PC-180-10A-14

ASCII MUX: RS 232, Connectorized, -48VDC.

8

D-PC-180-10A-XV

March 1997

4955 East Yale Avenue - Fresno, CA 93727 - Phone (559) 454-1600 / (800) 622-3314 - FAX (559) 454-1688

e-mail: [email protected]

Visit our Web site at http://www.dpstele.com

DPS INC

"Your Partners in Telemetry Monitoring Systems"

Summary of Contents for ASCII MUX

Page 1: ...ted with each port is a docking module socket that allows the physical interface to the outside world to be configured to match the as sociated communications channel or device This model of the ASCII...

Page 2: ...to the Configuration Section below for more information Configuration The MUX is configured with a program called T ASCMUX T ASCMUX runs under a host program called T Config which can host configurati...

Page 3: ...ch of the eight ports and the MUX common Port in this screen Parameters and their val ues are explained in Table B Table B Field Descriptions for the Edit Configuration Screen Field Description Msg Ti...

Page 4: ...eference to see how a partic ular unit is configured Several configurations can be reported A query box will ask for starting and ending configuration names press Tab to see a default box listing of e...

Page 5: ...RED Receiving data on common port BLINKING GREEN Transmitting Data on common port ER1 RED Error condition CFG RED Needs download GREEN Normal mode A1 A4 RED Alarm point active RLY RED Control relay op...

Page 6: ...23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 CTS PORT 7 TXD PORT 7 N C CTS PORT 8 TXD PORT 8 N C N C N C CTRL 1 CO...

Page 7: ...le H Field Descriptions for the Remote Parame ters Screen Job 30 and Up Field Description Job Phantom port number Jobs 30 to 157 will be available once a device has been defined as 8 Port ASCII MUX Po...

Page 8: ...00 2400 and 9600 Baud All specifications are subject to change without notice Options Model Numbers The ASCII MUX part numbers and options are listed below These options are constantly expanded As a r...

Reviews: