A-4
INSTALLATION
IN GENERAL
Take off the packaging material with care. Take off all the material used for packing and
accessories.
Each unit is set up to be used with the type of gas and electrical supply specified on the data plate
fixed on the appliance.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE
REGULATIONS AND RULES IN FORCE WITHIN THE DESIGNATED COUNTRY OF
DESTINATION.
1. To the certified gas technician.
The burner used is adjusted and sealed for use with the gas indicated on the nameplate. It is
nevertheless possible to convert the burner to another gas. These modifications must be
completed by a certified gas technician to conform to the EN 203-1:1993 (as amended)
standard.
The installation shall be made with a connector that complies with the standard EN 203-1:1993
(as amended)
Clean the air contained in the gas supply pipe at the installation to insure a successful firing on
the first try. The gas pipe sealing compound tightness must be verified using a solution of water
and soap prior to firing the unit.
NOTE:
If there's any modification done to the system or change of the type of gas used, make
sure that the regulator pressure of the burner is adjusted as recommended in this manual.
2. To the electrician.
Electrical supply installation must be in accordance with the electrical rating on the nameplate.
Verify if the motor is running in same direction as indicated by the arrow on the motor.
If it’s not the case;
If it’s a three phases motor and if the order of phase isn’t correct, the motor is running in the
wrong direction. This will affect the baking quality. You have to cut off the power supply and
interchange two phases to restore the situation.
WARNING
The electrician must make sure that the supply cable does not come in contact with the
oven top which becomes hot.
Summary of Contents for FC18GEU
Page 11: ...A 9 ...
Page 12: ...A 10 ...
Page 22: ...A 20 ...
Page 24: ...A 22 INSTRUCTIONS TO REMOVE THE BELT ON THE CONVEYOR ...
Page 25: ...A 23 ...
Page 26: ...A 24 ...
Page 27: ...A 25 ...
Page 30: ...SECTION B DIMENSIONS ...
Page 31: ...B 1 ...
Page 32: ...B 2 ...
Page 33: ...B 3 ...
Page 34: ...B 4 ...
Page 35: ...B 5 ...
Page 36: ...B 6 ...
Page 37: ...B 7 ...
Page 38: ...B 8 ...
Page 39: ...SECTION C BURNER AJUSTMENT ...
Page 40: ...C 1 ...
Page 41: ...C 2 ...
Page 42: ...C 3 ...
Page 43: ...C 4 ...
Page 44: ...SECTION D HEAT DIFFUSER ADJUSTMENT ...
Page 45: ...D 1 ...
Page 46: ...D 2 ...
Page 47: ...D 3 ...
Page 48: ...D 4 ...
Page 49: ...SECTION E COMPONENT PARTS ...
Page 50: ...E 1 ...
Page 52: ...E 3 ...
Page 54: ...E 5 ...
Page 56: ...E 7 ...
Page 58: ...E 9 ...
Page 60: ...E 11 ...
Page 62: ...SECTION G ELECTRIC SCHEMATICS ...
Page 63: ...G 1 ...
Page 64: ...G 2 ...
Page 65: ...40 ...