background image

E-11

13

7

6

12

11

10

9

8

5

4

3

2

1

OFF

60

100

150

200

250

POWER

40

60

80

100

120

140

150

160

170

180

190

200

210

220

230

240

Cooper

16

14

15

ROTATING

DRPR4S

DRPR4S

All manuals and user guides at all-guides.com

Summary of Contents for DRP3

Page 1: ...troduction A1 Shipping A2 Installation warnings A2 Distances to respect A3 Operation A4 Maintenance and cleaning A5 For more information please contact our office A6 SECTION B DIMENSIONS DRP3 B1 DRPR3...

Page 2: ...230V 1PH 50 Hz G4 DRP4 120V 1PH G5 DRPR4 120V 1PH G6 DRPR4 120V 1PH 1 DOOR SWITCH G7 DRPR4 120V 1PH 2 DOOR SWITCH G8 DRP4 230V 1PH 50 Hz G9 DRPR4 230V 1PH 50 Hz G10 Warranty FAMDRP3A DOC Rev 31 03 05...

Page 3: ...SECTION A DESCRIPTION All manuals and user guides at all guides com...

Page 4: ...a reliable service for years to come A nameplate specifies the model number serial number voltage amperage frequency and manufacturing date Drawings electrical diagram and replacement parts numbers ar...

Page 5: ...rrier has left contact immediately the freight company in order that they do their inspection We do not assume the responsibility for damages or losses that may occur during transportation INSTALLATIO...

Page 6: ...the back the top and the sides of the warmer GENERALITIES Take off the packaging material with care Take off all the material used for packing and accessories This equipment can be plugged on any netw...

Page 7: ...the switch on 3 Adjust the thermostat at 175 F DRP3R DRPR4 1 Fill the pan with water 2 Turn the two switches on 3 Adjust the thermostat at 175 F To stop the rotation of the rack only turns the right...

Page 8: ...ector It avoids food from sticking to the metal We recommend and sell 316 Silicone base protector and lubricant for oven Dow Corning Part number EXS400 Clean the warmer windows with products like Bras...

Page 9: ...OYON EQUIPMENT INC 1255 rue Principale C P 250 Lini re Qc Canada G0M 1J0 Tel 1 418 685 3431 Canada 1 800 463 1636 U S 1 800 463 4273 FAX 1 418 685 3948 Internet http www doyon qc ca E Mail doyon doyon...

Page 10: ...SECTION B DIMENSIONS All manuals and user guides at all guides com...

Page 11: ...3 8 21 3 4 20 1 2 OFF 60 10 0 150 200 25 0 POWER ROTATING 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper DRP3 DRP3 All manuals and user guides at all guides com a l l g u i d e s...

Page 12: ...B 2 Cooper 240 230 220 210 200 190 180 170 160 150 140 120 100 80 60 40 ROTATING POWER 25 0 200 150 10 0 60 OFF 20 1 2 21 3 4 21 3 8 DRPR3 DRPR3 All manuals and user guides at all guides com...

Page 13: ...B 3 25 3 4 23 7 8 22 1 2 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper DRP4 DRP4 All manuals and user guides at all guides com...

Page 14: ...B 4 30 3 4 23 7 8 22 1 2 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper ROTATING DRPR4 DRPR4 All manuals and user guides at all guides com...

Page 15: ...B 5 26 1 2 23 7 8 22 1 2 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper DRP4S DRP4S All manuals and user guides at all guides com...

Page 16: ...2 23 7 8 22 1 2 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper ROTATING DRPR4S DRPR4S All manuals and user guides at all guides com a l l g u i d e...

Page 17: ...SECTION E COMPONENT PARTS All manuals and user guides at all guides com...

Page 18: ...E 1 13 14 7 6 12 11 10 9 8 5 4 3 2 1 OFF 60 10 0 150 200 25 0 POWER ROTATING 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper DRP3 DRP3 All manuals and user guides at all guides com...

Page 19: ...STRAIGHT ELEMENT 120V 1000W 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG CORD 1 9 ELT610 THERMOSTAT 250F 1 ELT622 THERMOSTAT BEZEL 1 ELT615 THERMOSTAT KNOB 25...

Page 20: ...Cooper 240 230 220 210 200 190 180 170 160 150 140 120 100 80 60 40 ROTATING POWER 25 0 200 150 10 0 60 OFF 1 2 3 4 5 8 9 10 11 12 6 7 14 16 15 13 DRPR3 DRPR3 All manuals and user guides at all guides...

Page 21: ...ODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG CORD 1 9 ELT610 THERMOSTAT 250F 1 ELT622 THERMOSTAT BEZEL 1 ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40 240 F 1 12 ELI63...

Page 22: ...E 5 13 14 7 6 12 11 10 9 8 3 2 1 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper 4 5 DRP4 DRP4 All manuals and user guides at all guides com...

Page 23: ...ING ELEMENT 1250 WATTS 120 VOLTS 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG CORD 1 9 ELT610 THERMOSTAT 250F 1 ELT622 THERMOSTAT BEZEL 1 ELT615 THERMOSTAT KNO...

Page 24: ...16 13 7 6 12 11 10 9 8 3 2 1 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper 4 5 ROTATING 14 15 DRPR4 DRPR4 All manuals and user guides at all guides...

Page 25: ...1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG CORD 1 9 ELT610 THERMOSTAT 250F 1 ELT622 THERMOSTAT BEZEL 1 ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40 240...

Page 26: ...7 6 12 11 10 9 8 5 4 3 2 1 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper DRP4S DRP4S All manuals and user guides at all guides com a l l g u i d e...

Page 27: ...ING ELEMENT 1250 WATTS 120 VOLTS 1 OR ELE124 STRAIGHT ELEMENT 240V 1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG CORD 1 9 ELT610 THERMOSTAT 250F 1 ELT622 THERMOSTAT BEZEL 1 ELT615 THERMOSTAT KNO...

Page 28: ...3 7 6 12 11 10 9 8 5 4 3 2 1 OFF 60 10 0 150 200 25 0 POWER 40 60 80 100 120 140 150 160 170 180 190 200 210 220 230 240 Cooper 16 14 15 ROTATING DRPR4S DRPR4S All manuals and user guides at all guide...

Page 29: ...1500W FOR MODEL 220V 50HZ 1 8 ELF015 120V MALE PLUG CORD 1 9 ELT610 THERMOSTAT 250F 1 ELT622 THERMOSTAT BEZEL 1 ELT615 THERMOSTAT KNOB 250F 1 10 ELL650 RED PILOT LIGHT 1 11 RFTH06 THERMOMETER 40 240...

Page 30: ...SECTION G ELECTRIC SCHEMATIC All manuals and user guides at all guides com...

Page 31: ...COOLING FAN 40 W L1 N SWITCH ON OFF BULB P L DRP3 120V 60 Hz 31 03 05 M FAUCHER 2 2 6 7 9 STANDARD DRP3R_1 1 1 120 8 5 8 5 TOTAL POWER 1 0 Kw 60 Hz All manuals and user guides at all guides com a l l...

Page 32: ...1000 W COOLING FAN M MOTOR SWITCH 40 W L1 N SWITCH ON OFF BULB P L DRPR3 120V 60 Hz 31 03 05 M FAUCHER 2 2 6 ROTATIF DRP3R_1 1 1 120 9 0 9 0 TOTAL POWER 1 1 Kw 60 Hz All manuals and user guides at all...

Page 33: ...OLING FAN 40 W L1 N SWITCH ON OFF BULB P L 1260 W ELEMENT DRP3 230V 50 Hz 31 03 05 M FAUCHER 2 2 5 7 9 STANDARD DRP3R_1 1 1 230 6 0 6 0 TOTAL POWER 1 4 Kw 50 Hz All manuals and user guides at all guid...

Page 34: ...FAN M MOTOR SWITCH 40 W L1 N SWITCH ON OFF BULB P L 1260 W ELEMENT DRPR3 230V 50 Hz 31 03 05 M FAUCHER 2 2 5 ROTATIF DRP3R_1 1 1 230 6 5 6 5 TOTAL POWER 1 5 Kw 50 Hz All manuals and user guides at all...

Page 35: ...ENT 1250 W COOLING FAN L1 N L2 SWITCH ON OFF BULB P L DRP4 120V 60 Hz 31 03 05 M FAUCHER 2 2 3 4 6 7 9 STANDARD DRP4R_1 1 1 120 11 0 11 0 TOTAL POWER 1 3 Kw 60 Hz All manuals and user guides at all gu...

Page 36: ...G FAN M MOTOR SWITCH L1 N L2 SWITCH ON OFF BULB P L DRPR4 120V 60 Hz 31 03 05 M FAUCHER 2 2 3 6 ROTATIF DRP4R_1 1 1 120 11 5 11 5 TOTAL POWER 1 4 Kw 60 Hz All manuals and user guides at all guides com...

Page 37: ...G FAN M MOTOR SWITCH L1 N L2 SWITCH ON OFF BULB P L DOOR SWITCH DRPR4 120V 60 Hz 31 03 05 M FAUCHER 2 3 6 7 ROTATIF DOOR SWITCH DRP4R_1 1 1 120 11 5 11 5 TOTAL POWER 1 4 Kw 60 Hz All manuals and user...

Page 38: ...M MOTOR SWITCH L1 N L2 SWITCH ON OFF BULB P L DOOR SWITCH SWITCH DOOR DRPR4 120V 60 Hz 31 03 05 M FAUCHER 2 4 6 7 ROTATIF DOOR SWITCH2 DRP4R_1 1 1 120 11 5 11 5 TOTAL POWER 1 4 Kw 60 Hz All manuals an...

Page 39: ...LING FAN L1 N L2 SWITCH ON OFF BULB P L 1260 W ELEMENT DRP4 230V 50 Hz 31 03 05 M FAUCHER 2 2 3 4 5 7 9 STANDARD DRP4R_1 1 1 230 6 0 6 0 TOTAL POWER 1 4 Kw 50 Hz All manuals and user guides at all gui...

Page 40: ...FAN M MOTOR SWITCH L1 N L2 SWITCH ON OFF BULB P L 1260 W ELEMENT DRPR4 230V 50 Hz 31 03 05 M FAUCHER 2 2 3 5 ROTATIF DRP4R_1 1 1 230 6 5 6 5 TOTAL POWER 1 5 Kw 50 Hz All manuals and user guides at al...

Page 41: ...installed operated under normal conditions with proper supervision and to perform periodic preventive maintenance If any parts are proven defective during the period of one year from date of purchase...

Reviews: