background image

LIMITED WARRANTY

(Continental United States Of America And Canada Only)

Doyon Equipment Inc. guarantees to the original purchaser only that its product are free of
defects in material and workmanship, under normal use.

This warranty does not cover any light bulbs, thermostat calibration or defects due to or
resulting from handling, abuse, misuse, nor shall it extend to any unit from which the serial
number has been removed or altered, or modifications made by unauthorized service personnel
or damage by flood, fire or other acts of God. Nor will this warranty apply as regards to the
immersion element damaged by hard water.

The extent of the manufacturer’s obligation under this warranty shall be limited to the
replacement or repair of defective parts within the warranty period. The decision of the
acceptance of the warranty will be made by Doyon Equipment service department, which
decision will be final.

The purchaser is responsible for having the equipment properly installed, operated under normal
conditions with proper supervision and to perform periodic preventive maintenance.

If any parts are proven defective during the period of one year from date of purchase, Doyon
Equipment Inc. hereby guarantees to replace, without charge, F.O.B. Linière, Quebec, Canada,
such part or parts.

Doyon Equipment Inc. will pay the reasonable labor charges in connection with the replacement
parts occurring within one year from purchase date. Travel over 50 miles, holiday or overtime
charges are not covered. After one year from purchase date, all labor and transportation charges
in connection with replacement parts will be the purchaser’s responsibility.

Doyon Equipment Inc. does hereby exclude and shall not be liable to purchaser for any
consequential or incidental damages including, but not limited to, damages to property,
damages for loss of use, loss of time, loss of profits or income, resulting from any breach or
warranty.

In no case, shall this warranty apply outside Canada and continental United States unless the
purchaser has a written agreement from Doyon Equipment Inc.

Summary of Contents for AEF 035

Page 1: ...ATA 3 1 General description 3 3 2 Technical characteristics 4 3 3 Electrical characteristics 4 3 4 Damage situations 4 3 5 Electric installation 4 3 6 Security system 6 3 7 Control panel 6 3 8 Emergen...

Page 2: ...ENANCE 5 1 When the machine is new 17 5 2 Every day 17 5 3 Every 6 months 18 CHAPTER 6 SAFETY INSTRUCTIONS 6 1 Safety instructions 19 6 2 Hazards 19 ELECTRIC SCHEMATICS AEF015 21 AEF 035 050 080 100 1...

Page 3: ...designed to be used by qualified people in the Bakery production The particular shapes and speeds of the spirals and bowls allow you to have in a short period of time very smooth dough even when smal...

Page 4: ...kg Dough Capacity Lbs kg AEF 015 38 98 5 28 73 16 40 5 2 30 1 15 3 50 1 5 25 AEF 035 46 118 5 41 104 21 54 5 5 75 2 35 8 130 3 5 60 AEF 050 51 129 5 46 117 27 68 5 7 110 3 50 12 175 5 5 80 AEF 080 54...

Page 5: ...olts Speed 900 R P M for 1st speed and 1800 R P M for 2nd speed Frequency 60 Hz 208 240 volts 3 phases 4 wires 3 lines gnd 3 4 THE MANUFACTURER IS NOT RESPONSIBLE FOR THE MACHINE S DAMAGES IN THE FOLL...

Page 6: ...AEF A DOC 02 2003 5 Figure 3 1 Control panel 2 Machine structure 3 Security bars 4 Spiral 5 Bottom body 6 Stainless steel bowl 7 Machine floor fixer 8 Roller 9 Side board 10 Main switch 10...

Page 7: ...and press the green button start It is forbidden to remove modify or damage the machine s security bars 3 7 CONTROL PANEL AEF 015 fig 2 Start button GREEN If you push it the machine will start Stop b...

Page 8: ...e selector button 8 Emergency stop 9 Display to visualise the programs 10 Programming button 11 Up button 12 Down button 13 Display to visualise the time of 1st speed 14 Display to visualise the time...

Page 9: ...A DOC 02 2003 8 Figure 5 1 Micro switch 2 Control panel 3 Electric motor 4 Electric motor 5 Security bars 6 Current transformer 7 Switch 8 Contactor 9 Electric plug 10 Electric cable cord 11 Main swi...

Page 10: ...cy STOP is not pressed fig 2 If it is you must turn the button as shown by the arrows 4 Press the green button and verify if the bowl and spiral rotation is the same as indicated by the arrow If not s...

Page 11: ...and a light will lighten up fig 2 At the end of the working cycle stop the machine by pressing the red Stop button and the light on the start stop switch will shut off You may stop the machine at any...

Page 12: ...achine and easily accessible 4 3 START 1 Turn the general switch into position I and verify if the Emergency Stop is unlocked and the points 2 and 3 will display 4bars _ _ _ _ 2 If the red emergency S...

Page 13: ...lose the safety bars point 3 fig 3 If you lift up the bars the machine will stop immediately Press POWER point 1 fig 4 the time display point 2 and 3 fig 4 will display 0 00 The machine starts in manu...

Page 14: ...on point 1 fig 4 the display point 2 and 3 fig 4 will light up Close the safety bars point 3 fig 3 If you lift up the bars the machine will stop immediately The machine starts in manual mode to change...

Page 15: ...ime When the working time is the same as the programmed time the machine will change speed automatically The 2nd speed lights the display point 4 fig 4 and in display point 2 and 3 fig 4 you will visu...

Page 16: ...you press continuously the stop button 16 you ll get out of the program When the working cycle is completed the stop button 16 will light Then if you press it the cycle will end and the equipment is r...

Page 17: ...data in the selected program you will have approximately 10 seconds between each step to enter the desired settings The data will not be saved if you exceed 10 seconds between two settings and the pr...

Page 18: ...e examined by removing the access panel on the bottom side of the machine c To verify if the belt needs to be stretched press the finger in the middle of the belt and if the looseness is superior to i...

Page 19: ...smission s belts of the spiral can be examined by opening the cover of the machine b The transmission s belts of the bowl can be examined by removing the access panel on the bottom side of the machine...

Page 20: ...stopped by using the red stop switch If you detect any damages or bad functions of the machine turn it off immediately and call for an authorised technician otherwise it may cause irreversible damages...

Page 21: ...id the risk of fire electric shocks personal and material damages Only qualified people may access the parts that have electric current which are obliged to 1 Stop the machine 2 Turn off the main swit...

Page 22: ...AEF A DOC 02 2003 21...

Page 23: ...AEF A DOC 02 2003 22...

Page 24: ...le for having the equipment properly installed operated under normal conditions with proper supervision and to perform periodic preventive maintenance If any parts are proven defective during the peri...

Reviews: