![Dovre VIRTUS 50GA Installation Instructions And Operating Manual Download Page 47](http://html.mh-extra.com/html/dovre/virtus-50ga/virtus-50ga_installation-instructions-and-operating-manual_2525177047.webp)
D
OVRE
Subject to change because of technical improvements
9
(50 mm). See following figure. If you decided on a
permitted duct route, the correct position for the
restriction plate follows from the appendix “Cal-
culation sheet for checking projected route”.
3
2
1
09-20022-046
Preparing the connection to
the flue
When connecting the stove to the flue, you can
choose to connect to the
top
or to the
back
of the
stove.
Connecting to the top
The stove is ready to be connected at the top upon
delivery.
When a pipe system from a manufacturer other
than Muelink & Grol is used, first use the
adapter belonging to that manufacturer’s pipe
system.
Connecting to the back
1. Remove the top plate.
2. Remove the heat shield (A) and break out the
cover.
09-20022-052
3. Remove cover plate (B) and its seal (3) on the
back.
4. Remove cover plate (C) and its seal (3) on the
back internally.
5. Remove the outer collar (1) and its seal (3) at the
top.
6. Remove the inner collar (2) and its seal (3).
7. Fit the inner collar (2) and the outer collar (3) with
their respective seals (3) to the back of the appli-
ance.
8. Fit the cover plates (B) and (C) and their respect-
ive seals (3) to the top of the appliance.
9. Replace the heat shield (A).
10. Fit the top plate.
1
3
2
4
4
A
B
3
C
3
PH2
09-20022-049