![Dovre TAI 45C Installation Instructions And Operating Manual Download Page 56](http://html1.mh-extra.com/html/dovre/tai-45c/tai-45c_installation-instructions-and-operating-manual_2525175056.webp)
Model
55M
55M
55M
55C
Nominal output
11 kW
11 kW
11 kW
11 kW
Flue connection (diameter)
150 mm
150 mm
150 mm
150 mm
Weight
190 kg
190 kg
190 kg
175 kg
Recommended fuel
Wood
Coal
Brown coal
Coal
Fuel property, max. length wood
55 cm
12/22 - 20/30
3" - 6" - 7"
12/22 - 20/30
Mass flow of flue gasses
8.2 g/s
7.7 g/s
9.0 g/s
7.7 g/s
Temperature increase measured in
the measuring section
318 °C
339 °C
364 °C
339 °C
Temperature measured at appliance
exit
407 °C
446 °C
453 °C
446 °C
Minimum draught
12 Pa
12 Pa
12 Pa
12 Pa
CO emission (13%O
2
)
0.09%
0.09%
0.09%
0.09%
NOx emission (13% O
2
)
109 mg/Nm³
60 mg/Nm³
129 mg/Nm³
60 mg/Nm³
CnHm emission (13%O
2
)
62 mg/Nm³
117 mg/Nm³
49 mg/Nm³
117 mg/Nm³
Particulate emission (13%O
2
)
5.1 mg/Nm³
4 mg/Nm³
32 mg/Nm³
4 mg/Nm³
Particulate emission in accordance
with NS3058-NS3059
-
-
-
-
Efficiency
75.30%
78.2%
75.2%
78.2%
24
Subject to change because of technical improvements
Summary of Contents for TAI 45C