![Dovre TAI 45C Installation Instructions And Operating Manual Download Page 55](http://html1.mh-extra.com/html/dovre/tai-45c/tai-45c_installation-instructions-and-operating-manual_2525175055.webp)
Appendix 1: Technical data
Model
45M
45M
45M
45C
Nominal output
9 kW
9 kW
9 kW
9 kW
Flue connection (diameter)
150 mm
150 mm
150 mm
150 mm
Weight
155 kg
155 kg
155 kg
160 kg
Recommended fuel
Wood
Coal
Brown coal
Coal
Fuel property, max. length wood
45 cm
12/22 - 20/30
3" - 6" - 7"
12/22 - 20/30
Mass flow of flue gasses
8.5 g/s
7.6 g/s
8.8 g/s
7.6 g/s
Temperature increase measured in
the measuring section
273 °C
282 °C
286 °C
282 °C
Temperature measured at appliance
exit
410 °C
389 °C
395 °C
389 °C
Minimum draught
12 Pa
12 Pa
12 Pa
12 Pa
CO emission (13%O
2
)
0.09%
0.08%
0.07%
0.09%
NOx emission (13% O
2
)
91 mg/Nm³
86 mg/Nm³
158 mg/Nm³
86 mg/Nm³
CnHm emission (13%O
2
)
96 mg/Nm³
136 mg/Nm³
109 mg/Nm³
136 mg/Nm³
Particulate emission (13%O
2
)
13 mg/Nm³
4 mg/Nm³
13 mg/Nm³
4 mg/Nm³
Particulate emission in accordance
with NS3058-NS3059
-
-
-
-
Efficiency
75.30%
79.50%
75%
79.50%
Subject to change because of technical improvements
23