2.1 Ignition
Open the gas valve fitted in the gas pipe to the appliance.
Turn the thermostat knob to the ignition position (pilot) and press (hold it in pressed
position).
Press the ignition knob until you hear a "click" – this is the ignition spark.
You can see whether the pilot light is burning through the glass window. If necessary click
repeatedly until the pilot light ignites.
When the pilot light is burning, hold the thermostat knob depressed for a further 30
seconds and then release gently.
If the pilot light stops burning, wait five minutes and then repeat the procedure.
The rear burner is ignited by turning the thermostat knob to the desired position (position
1= low setting, position 6 = high setting).
Turning the slider on the hand tap to the right ignites the front burner, at least if the
thermostat knob is between 1 and 6.
Warning: If the pilot light goes out, you must wait at least five minutes before re-igniting
the appliance.
2.3 Using the effects burner (front burner)
The front burner will only light if you open the hand tap. Start it by pulling out the knob and
turning it to the left. Turn if off by turning the knob to the right, pulling out and releasing it.
Make sure that the front burner has gone out.
2.4 Extinguishing the stove
To extinguish the stove completely, put the thermostat knob in the "off" position and press
in. The pilot light will then go out.
If the stove is not to be used for a long period, it is also advisable to close the gas cut-off
valve in the inlet pipe.
2.5 Outlet protection
The appliance is fitted with thermal outlet protection which cuts out the pilot light and thus
turns off the main burner in the event of leakage of combustion gases from the draught
diverter.
The protective device is a thermostat which opens an electrical contact if a set
temperature is exceeded and thus interrupts power to the thermocouple. This causes the
control block to turn off the gas supply to the main burner and pilot light.
The appliance can only be relit when the protective device has cooled down. The
thermostat cannot just be switched off. Call your installer if the outlet protection is
activated frequently.
Summary of Contents for 750 GA
Page 8: ...wijzigingen op grond van technische verbeteringen voorbehouden 8 5 Afmetingen 750 GA P...
Page 15: ...wijzigingen op grond van technische verbeteringen voorbehouden 15 5 Dimensions 750 GA P...
Page 22: ...wijzigingen op grond van technische verbeteringen voorbehouden 22 5 Dimensions 750 GA P...
Page 29: ...wijzigingen op grond van technische verbeteringen voorbehouden 29 5 Abmessungen 750 GA P...
Page 30: ......