1 Installation instructions
The installation and start-up must be carried out by specialist installers in accordance
with the NBN D51-003 standard.
During installation, have your installer explain how to use, operate and maintain your
appliance.
Each appliance is tested, carefully adjusted and sealed in the factory in accordance with
category I2E+ (natural gas) or category I3+ (propane/butane). See the identification plate
for the type of gas for which your appliance is adapted. Any modifications of the controls
by unauthorised persons will invalidate the warranty.
1.1 Choosing a location
Keep the connection between the connection collar and the flue pipe as short and
straight as possible. The minimum distance from the appliance to a flammable wall is
20 cm. Ensure that there are no curtains hanging above the appliance.
Combustion consumes oxygen. It is therefore very important that the space in which the
appliance is installed is adequately ventilated. Install ventilation of at least 15 cm² (not
closable).
1.2 Connection to the flue pipe
The flue pipe must comply with the rules described in standard NBN B61-001.
Before connecting the appliance to a flue pipe to which a coal, wood or oil-fired stove
was previously connected, it is best to have the flue professionally cleaned. Although
a gas stove can operate with a very small flue draught, we advise you to have the flue
checked every year.
The appliance is connected to the flue using a 100 mm diameter discharge pipe fitted
into the connection collar on the rear wall. The cover sits on top of the top plate. Use
corrosion-resistant materials.
This connection pipe should never come below the connection collar of the stove.
Check whether the flue is working correctly by operating the appliance at full capacity
for ten minutes before holding a cold mirror or chromed object to the draught diverter
(behind the appliance below the connection collar). If the mirror or object mists up, the
flue is not functioning sufficiently.
Summary of Contents for 750 GA
Page 8: ...wijzigingen op grond van technische verbeteringen voorbehouden 8 5 Afmetingen 750 GA P...
Page 15: ...wijzigingen op grond van technische verbeteringen voorbehouden 15 5 Dimensions 750 GA P...
Page 22: ...wijzigingen op grond van technische verbeteringen voorbehouden 22 5 Dimensions 750 GA P...
Page 29: ...wijzigingen op grond van technische verbeteringen voorbehouden 29 5 Abmessungen 750 GA P...
Page 30: ......