![Dovre 2180CBBS Installation Instructions And Operating Manual Download Page 36](http://html1.mh-extra.com/html/dovre/2180cbbs/2180cbbs_installation-instructions-and-operating-manual_2525181036.webp)
Floors and walls
The floor on which the appliance is placed must have
sufficient bearing capacity. For the weight of the
appliance, see the appendix "Technical data".
There may not be any electrical wires in the
floor below the appliance and in the walls
around it.
All flammable materials must be removed from
under the appliance or protected by at least a 6
cm concrete slab.
Flammable walls bordering the appliance must
be protected by at least a 10 cm stone wall and
5 cm insulation.
Protect non-flammable walls bordering the
appliance with at least 2.5 cm insulation to
avoid cracking.
Protect a flammable floor from heat radiation
and falling ash by means of a fireproof
protective plate. See the appendix "Distance
from combustible material".
Keep enough distance between the appliance
and combustible materials such as furniture.
Ensure sufficient ventilation around flammable
materials such as a mantelpiece. See
appendix "Distance from combustible
material".
Carpets and rugs must be at least 80 cm away
from the fire.
Do not place any flammable materials within
50 cm of any convection outlets.
Product description
1. Connection collar
2. Damper
3. Latch
4. Damper operation
5. Primary air slide
6. Secondary air slide
7. Door
8. Bottom of the fire compartment
Features of the appliance
The appliance is fitted with a removable fire plate,
log retainer and fire plate.
Cast iron inner plates protect the combustion
chamber and dissipate heat to the
environment.
The appliance comes standard with a connection
kit for the outside air supply.
The appliance has a connection collar which can
take a vertical connection as well as a 45°
connection.
The appliance is supplied with a separate handle
(A) , the so-called 'cold hand', for opening the door;
see next figure.
6
Subject to change because of technical improvements
Summary of Contents for 2180CBBS
Page 24: ...2180CBBS 09 20017 026 24 Wijzigingen op grond van technische verbeteringen voorbehouden...
Page 25: ...Wijzigingen op grond van technische verbeteringen voorbehouden 25 2180CBGD 09 20017 028...
Page 31: ......
Page 54: ...2180CBBS 09 20017 026 24 Subject to change because of technical improvements...
Page 55: ...2180CBGD 09 20017 028 Subject to change because of technical improvements 25...
Page 61: ......
Page 85: ...2180CBBS 09 20017 026 Sous r serve de modifications dues des am liorations techniques 25...
Page 86: ...2180CBGD 09 20017 028 26 Sous r serve de modifications dues des am liorations techniques...
Page 115: ...2180CBBS 09 20017 026 nderungen aufgrund technischer Verbesserungen vorbehalten 25...
Page 116: ...2180CBGD 09 20017 028 26 nderungen aufgrund technischer Verbesserungen vorbehalten...
Page 145: ...2180CBBS 09 20017 026 Dovre se reserva el derecho de realizar cambios por razones t cnicas 25...
Page 146: ...2180CBGD 09 20017 028 26 Dovre se reserva el derecho de realizar cambios por razones t cnicas...
Page 175: ...2180CBBS 09 20017 026 Con riserva di modifiche per miglioramenti tecnici 25...
Page 176: ...2180CBGD 09 20017 028 26 Con riserva di modifiche per miglioramenti tecnici...
Page 182: ......