Dover WILDEN BioPharm T2 Series Engineering, Operation & Maintenance Download Page 10

8

WILDEN PUMP & ENGINEERING, LLC

SECTION 7C

TROUBLESHOOTING

Pump will not run or runs slowly.

1. Check air inlet screen and air filter for debris.
2. Check for sticking air valve, flush air valve in solvent.
3. Check for worn out air valve. If piston face in air valve is

shiny instead of dull, air valve is probably worn beyond
working tolerances and must be replaced.

4. Check center block Glyd™ rings. If worn excessively, they

will not seal and air will simply flow through pump and out
air exhaust. Use only Wilden Glyd™ rings as they are of
special construction.

5. Check for rotating piston in air valve.
6. Check type of lubricant being used. A higher viscosity oil

than suggested may cause the piston to stick or run errat-
ically. Wilden suggests the use of an oil with arctic charac-
teristics (ISO 15-5 wt.).

Pump runs but little or no product flows.

1. Check for pump cavitation; slow pump speed down to

match thickness of material being pumped.

2. Check for sticking ball check valves. If material being

pumped is not compatible with pump elastomers, swelling
may occur. Replace ball check valves and o-rings with the
proper elastomers.

3. Check to make sure all suction connections are air tight,

especially clamp bands around intake balls.

Pump air valve freezes.

Check for excessive moisture in compressed air. Either
install dryer or hot air generator for compressed air.

Air bubbles in pump discharge.

1. Check for ruptured diaphragm.
2. Check tightness of clamp bands, especially at intake manifold.

Product comes out air exhaust.

1. Check for diaphragm rupture.
2. Check tightness of piston plates to shaft.

SECTION 7G – SOLENOID OPERATION

TROUBLESHOOTING

Pump will not run.

1.

Check for pressurized air at the inlet. 3.10 bar (Min. 45 psig.)

2.

Check air inlet and filter for debris.

3.

Connect a test lamp to the two wires which run to pump

and ensure that the lamp cycles on and off.
4.

Make sure that the air valve manual override (small red

knob on front of valve) is switched to the “0” position.
5.

Check pilot pressure vent at the top of the operator/coil

assembly to ensure that it is not clogged.
6.

Check for a worn out air valve. If air continually blows out

the exhaust in very large quantities, the air valve seals may be
worn beyond their ability to function. In this case, the valve
must be replaced.
NOTE: Before the valve is scrapped, it is possible that it may
be saved by completely disassembling the valve, cleaning all
components and relubricating the valve.

Pump runs but little or no fluid comes out.

1.

Check that the discharge isolation valve is not closed.

2.

Check that the electronic signal is slow enough that the

pump is able to complete each physical stroke before it is
signaled to change direction. The time required to complete the
stroke is determined by a variety of factors which include fluid
viscosity and head pressure. The shaft can be viewed if the
muffler is removed to verify that the pump is stroking.
3.

Check for pump cavitation; slow pump speed down to

match the thickness of the material being pumped.
4.

Check for sticking ball check valves. If the material being

pumped is not compatible with the pump elastomers, swelling
may occur. Replace ball check valves and O-ring with the
proper elastomers.
5.

Check to make sure that all suction connections are air

tight, and that the clamp bands are properly tightened.

Pump air passages blocked with ice.

Check for excessive moisture in compressed air line. As the
air expands out the exhaust during the operation of the pump,

water vapor entrapped in the compressed air can freeze and
block the air passageways in the pump. If this occurs, it may
be necessary to install a coalescing filter, an air dryer, or a hot
air generator for the compressed air.

Air bubbles in pump discharge.

1.

Check for ruptured diaphragm.

2.

Check tightness of clamp bands, and the integrity of the

O-rings, especially at intake manifold.

Product comes out air exhaust.

1.

Check for diaphragm rupture.

2.

Check tightness of piston plates to shaft.

Pump rattles.

1.

See E9 Troubleshooting Guide.

2.

Create false discharge head or suction lift.

Solenoid buzzes or solenoid burnout.

1.

Incorrect voltage, faulty or dirty solenoid.

Solenoid valve fails to shift electrically but shifts with
manual override.

1.

Incorrect voltage, defective coil or wiring.

Solenoid valve fails to shift electrically or with manual over-
ride.

1.

Inadequate air supply, contamination, inadequate or

improper lubrication, mechanical binding in the valve.

Valve shifts but fails to return.

1.

Broken spring, mechanical binding.

Excessive leaking from air valve vent.

1.

Worn seals in air valve.

WIL_14070_E_01.qxd  1/4/06  6:29 AM  Page 8

Summary of Contents for WILDEN BioPharm T2 Series

Page 1: ...WIL_14070_E EOM T2M BIOPHARM 2 05 WIL_14070_E_01 qxd 1 4 06 6 29 AM Page C1...

Page 2: ...ATION AND OPERATION A Installation 6 B Operation Maintenance 7 C Troubleshooting 8 SECTION 8 DIRECTIONS FOR DISASSEMBLY REASSEMBLY A Model T2 METAL Disassembly Cleaning Inspection 9 B Turbo Flo Pump A...

Page 3: ...TY VARIES BY MODEL 900 BioPharm 901 BioPharm BSP 902 BioPharm DIN 903 BioPharm FDA Tri Clover flanges wing nuts 904 BioPharm USDA Food Master 905 BioPharm 3A CIP Wil Gard 110V 906 BioPharm 3A CIP Wil...

Page 4: ...d area FIGURE 2 When the pressurized diaphragm diaphragm A reaches the limit of its discharge stroke the air valve redirects pressurized air to the back side of diaphragm B The pressurized air forces...

Page 5: ...in the pump by turning it upside down and allowing any fluid to flow into a suitable container CAUTION Blow out air line for 10 to 20 seconds before attaching to pump to make sure all pipe line debris...

Page 6: ...0 P 8 0 3 R 32 1 3 BSP threads available DIMENSIONS T2 BIOPHARM ITEM METRIC mm STANDARD inch A 264 10 4 B 35 1 4 C 138 5 4 D 256 10 1 E 267 10 5 F 295 11 6 G 41 1 6 H 98 3 8 J 75 3 0 K 183 7 2 L 210 8...

Page 7: ...3 h 13 scfm air consumption See dot on chart Caution Do not exceed 8 6 bar 125 psig air supply pressure Flow rates indicated on chart were determined by pumping water For optimum life and performance...

Page 8: ...rime troubles will be eliminated In addition pump efficiency can be adversely affected if proper attention is not given to elevation see pump performance chart PIPING Final determination of the pump s...

Page 9: ...ecessary repairs and replacements Over a period of time such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime In addition accurate...

Page 10: ...rn beyond their ability to function In this case the valve must be replaced NOTE Before the valve is scrapped it is possible that it may be saved by completely disassembling the valve cleaning all com...

Page 11: ...model T2 has a 25 mm 1 inlet and 19 mm outlet and is designed for flows up to 95 lpm 25 gpm The single piece center section consisting of center block and air chambers is molded of polypropylene or al...

Page 12: ...tched or gouged Using an adjustable wrench remove diaphragm assembly from shaft Inspect all parts for wear and replace with genuine Wilden parts if necessary Figure 9 Step 4 Figure 4 Remove the discha...

Page 13: ...working tolerances and should be replaced If the piston does not move freely in the air valve the entire air valve should be immersed in a cleaning solution NOTE Do not force the piston by inserting a...

Page 14: ...r clamp bands to the desired torque see this page for torque specs Description of Part Metal Pumps Air Valve 3 4 N m 30 in lbs Outer Piston 38 0 N m 28 ft lbs Vertical Bolts 13 0 N m 115 in lbs MAXIMU...

Page 15: ...13 WILDEN PUMP ENGINEERING LLC NOTES WIL_14070_E_01 qxd 1 4 06 6 29 AM Page 13...

Page 16: ...14 WILDEN PUMP ENGINEERING LLC SECTION 9A EXPLODED VIEW PARTS LISTING T2 METAL AIR OPERATED TEFLON FITTED WIL_14070_E_01 qxd 1 4 06 6 29 AM Page 14...

Page 17: ...02 6802 08 14 Pistons Inner 2 02 3750 01 02 3750 01 02 3750 01 02 3750 01 02 3750 01 15 Pistons Outer 2 02 4600 03 02 4600 04 02 4600 03 02 4600 03 02 4600 04 16 Stud Bolt 2 02 6150 08 02 6150 08 02...

Page 18: ...ro Seal 37 Turcite 48 Expanded PTFE 49 Polyurethane 50 Polyurethane ester 51 Neoprene 52 Buna N Nitrile 53 Viton FKM 54 Nordel EPDM 55 Teflon PTFE 56 Saniflex Hytrel 57 FDA Wil Flex 58 Wil Flex 59 Tef...

Page 19: ...WIL_14070_E_01 qxd 1 4 06 6 29 AM Page BC1...

Page 20: ...WIL_14070_E_01 qxd 1 4 06 6 29 AM Page BC2...

Reviews: