I
NSTALLATION
18
C
HAPTER
1
1.7.4 S
ETTING
THE
SOLDERLEVEL
SENSOR
F
IGURE
1.21
S
OLDERLEVEL
SENSOR
1.
Check if the solderlevel is 15 mm from the top of the bath rim (without pumping).
2.
Turn on both solderwaves.
3.
Adjust the ring of the float so that it sensor is on.
1.7.5 F
OAMFLUXER
1.
Check if the fluxer is level. If necessary correct the threaded ends.
2.
Check if the drain is closed.
3.
Fill the fluxer up to the top of the overflow pipe with flux of the desired density.
4.
Fill the fluxsupply container or place the vessel of the fluxsupplier in the machine.
5.
Place the suctionpipe on the vessel/container.
6.
Switch on the fluxer.
7.
Check that the air supply is on with a pressure of max. 2.5 bar.
8.
Adjust the flow with the button on the pneumatic panel till the wave is 10 mm.
9.
Place the glassplate (or an empty PCB) in the conveyor to check if the underside is wetted
well with flux.
10. If necessary correct the wave height and control again.