Dover unified brands groen DH-20 Operator'S Manual Download Page 2

OM-DH(T) DOMESTIC & (CE) INTERNATIONAL

Available Options:
1.   2” (50.8 mm) tangent drawoff standard on DHT models
2.   Strainers, solid disk, 1/4” (6.35mm) or 1/8” (3.18mm) holes
3.   No. 31 lift-off cover
4.   No. 51 counterbalanced cover w/actuator*
5.   Basket Inserts (Tri-BC)
6.   Water fill faucets with swing spout
7.   Kettle Brush Kit

IMPORTANT - READ FIRST - IMPORTANT

IMPORTANT: THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN 

CONFORMITY WITH THE INSTALLATION AND SERVICING INSTRUCTIONS 

AND NATIONAL REGULATIONS IN FORCE AT THE TIME. PARTICULAR 

ATTENTION MUST BE PAID TO THE FOLLOWING (CE):
I. E. E. REGULATIONS FOR ELECTRICAL INSTALLATIONS
ELECTRICITY AT WORK REGULATIONS
GAS SAFETY (INSTALLATION & USE REGULATIONS
HEALTH AND SAFETY AT WORK ACT
FIRE PRECAUTIONS ACT
LOCAL AND NATIONAL BUILDING REGULATIONS

 

  DETAILED RECOMMENDATIONS ARE CONTAINED IN INSTITUTE OF GAS 

ENGINEERS PUBLISHED DOCUMENTS: IGE/UP/1, IGE/UP/2, BS6173 AND 

BS5440 (CE).

 

  THESE APPLIANCES HAVE BEEN CE-MARKED ON THE BASIS OF 

COMPLIANCE WITH THE GAS APPLIANCE DIRECTIVE, EMC AND LOW 

VOLTAGE DIRECTIVE FOR THE COUNTRIES, GAS TYPES AND PRESSURES 

AS STATED ON THE DATA PLATE.

WARNING:  TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC, 

MUST BE EARTHED.

 

  ON COMPLETION OF THE INSTALLATION, THESE INSTRUCTIONS SHOULD 

BE LEFT WITH THE ENGINEER-IN-CHARGE FOR REFERENCE DURING 

SERVICING. FURTHER TO THIS, THE USERS INSTRUCTIONS SHOULD 

BE HANDED TO THE USERS AND THE INSTALLER SHOULD INSTRUCT 

THE RESPONSIBLE PERSON(S) IN THE CORRECT OPERATION AND 

MAINTENANCE OF THE APPLIANCE. EMPHASIS SHOULD BE MADE WITH 

REGARD TO SAFE OPERATION OF DRAIN VALVE.

 

  IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED 

BEFORE INSTALLING AND COMMISSIONING THE APPLIANCE. FAILURE TO 

COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR 

THE NEED FOR A SERVICE CALL.

CAUTION:   SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
WARNING:  DISCONNECT POWER BEFORE SERVICING. FAILURE TO DISCONNECT 

COULD RESULT IN ELECTROCUTION AND DEATH.

CAUTION:   UNIT WEIGHS 535 TO 973 LB. (245 TO 400 KG). FOR SAFE HANDLING, 

INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE 

MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR 

PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE 

PLACE OF INSTALLATION.

WARNING:   INSTALLATION OF THE KETTLE MUST BE DONE BY PERSONNEL QUALIFIED 

TO WORK WITH GAS AND ELECTRICITY. IMPROPER INSTALLATION CAN 

RESULT IN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.

WARNING:  THIS UNIT IS DESIGNED FOR COMMERCIAL USE. NEVER USE HOME 

OR RESIDENTIAL GRADE GAS CONNECTIONS. THEY DO NOT MEET 

COMMERCIAL GAS CODES AND COULD BE HAZARDOUS.

DANGER:   ELECTRICALLY GROUND THE UNIT AT THE TERMINAL PROVIDED. FAILURE 

TO GROUND UNIT COULD RESULT IN ELECTROCUTION AND DEATH.

WARNING:  DO NOT CONNECT ANY PIPING TO THE POP SAFETY VALVE, THE VALVE 

MUST BE FREE TO VENT STEAM AS NEEDED. THE ELBOW ATTACHED TO THE 

SAFETY VALVE SHOULD POINT TO THE FLOOR. IMPROPER INSTALLATION 

WILL VOID WARRANTY.

WARNING:  FAILURE TO CHECK SAFETY VALVE OPERATION PERIODICALLY COULD 

RESULT IN PERSONAL INJURY AND/OR DAMAGE TO EQUIPMENT.

WARNING:  WHEN TESTING SAFETY VALVE, AVOID ANY EXPOSURE TO THE STEAM 

BLOWING OUT OF THE SAFETY VALVE. DIRECT CONTACT WITH STEAM 

COULD RESULT IN SEVER BURNS.

WARNING:   KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLE MATERIALS. 

FAILURE TO DO SO COULD RESULT IN FIRE OR PROPERTY DAMAGE.

CAUTION:   BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING 

INSTRUCTIONS, CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS 

MANUAL.

CAUTION:   KEEP FLOORS IN KETTLE WORK AREA CLEAN AND DRY. IF SPILLS OCCUR, 

CLEAN IMMEDIATELY TO AVOID THE DANGER OF SLIPS OR FALLS.

WARNING:   WHEN TILTING KETTLE FOR PRODUCT TRANSFER:

1) USE CONTAINER DEEP ENOUGH TO CONTAIN AND MINIMIZE PRODUCT 

SPLASHING.
2) PLACE CONTAINER ON STABLE, FLAT SURFACE, AS CLOSE TO KETTLE AS 

POSSIBLE.
3) STAND TO SIDE OF KETTLE WHILE POURING — NOT DIRECTLY IN POUR 

PATH OF HOT CONTENTS.
4) RETURN KETTLE BODY TO LEVEL POSITION AFTER CONTAINER IS FILLED OR 

TRANSFER IS COMPLETE.
5) DO NOT OVERFILL CONTAINER, AVOIDING DIRECT SKIN CONTACT WITH HOT 

CONTAINER AND ITS CONTENTS.

WARNING:  DO NOT HEAT AN EMPTY KETTLE. EXCESSIVE STEAM PRESSURE COULD 

DEVELOP.

WARNING:   IF THE KETTLE CONTAINS ITEMS IN HOT LIQUIDS SUCH AS SAUCE OR MELTED 

FAT, THEY CAN SLIDE FORWARD SUDDENLY DURING TILTING AND CAUSE THE 

HOT LIQUID TO SPLASH OUT.

WARNING:  AVOID ALL DIRECT CONTACT WITH HOT FOOD PRODUCT OR WATER IN THE 

KETTLE. DIRECT CONTACT COULD RESULT IN SEVERE BURNS.

CAUTION:  DO NOT OVER FILL THE KETTLE WHEN COOKING, HOLDING OR CLEANING. KEEP 

LIQUIDS A MINIMUM OF 2-3” (5-8 CM) BELOW THE KETTLE BODY RIM TO 

ALLOW CLEARANCE FOR STIRRING, BOILING AND SAFE PRODUCT TRANSFER.

WARNING:  IT IS RECOMMENDED THAT WATER AND SOLUTIONS BE KEPT OUT OF 

CONTROLS AND BURNERS. DO NOT USE HIGH PRESSURE SPRAY DIRECTLY ON 

THE CONTROL CONSOLE, ELECTRICAL CONNECTIONS AND BURNERS. USE A 

GARDEN HOSE SPRAY CONNECTED TO CITY WATER SUPPLY.

CAUTION:   MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES 

AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, 

GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ THE 

WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE 

USED. FAILURE TO DISCONNECT COULD RESULT IN ELECTROCUTION AND DEATH.

WARNING:   BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC 

POWER SUPPLY AND CLOSE THE MAIN GAS COCK. ALLOW FIVE MINUTES FOR 

UNBURNED GAS TO VENT.

CAUTION:   USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY 

AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND 

DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.

IMPORTANT:  SERVICE PERFORMED BY OTHER THAN GROEN AUTHORIZED SERVICE AGENT 

WILL VOID ALL WARRANTIES.

CAUTION:  THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND 

ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL 

CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN 

GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE 

IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED.

CAUTION:   CHILDREN SUPERVISED ARE NOT TO PLAY WITH THIS APPLIANCE.
CAUTION:  CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN 

WITHOUT SUPERVISION.

CAUTION:   FOR APPLIANCES INTENDED FOR USE AT ALTITUDES EXCEEDING 2,000 M, THE 

MAXIMUM ALTITUDE WILL BE STATED OR MARKED ON APPLIANCE.

PERFORMANCE DATA (DOMESTIC)

Model

DH/DHT-20

DH/DHT-40

DH/DHT-60

DH/DHT-80

BTU/hr

72,000

100,000

150,000

150,000

kW

21.1

29.3

44.0

44.0

Summary of Contents for unified brands groen DH-20

Page 1: ... Four stainless steel tubular legs support the unit Bullet or flanged feet on each of the legs can be adjusted to level the kettle Standard DHT units include a two inch tangent draw off valve The self contained steam source is heated by propane or natural gas Ignition is electronic The kettle is charged at the factory with chemically pure water which contains rust inhibitors The steam source provi...

Page 2: ... ANY EXPOSURE TO THE STEAM BLOWING OUT OF THE SAFETY VALVE DIRECT CONTACT WITH STEAM COULD RESULT IN SEVER BURNS WARNING KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLE MATERIALS FAILURE TO DO SO COULD RESULT IN FIRE OR PROPERTY DAMAGE CAUTION BE SURE ALL OPERATORS READ UNDERSTAND AND FOLLOW THE OPERATING INSTRUCTIONS CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL CAUTION KEEP FLO...

Page 3: ...LE WALLS MINIMUM CLEARANCE FROM NON COMBUSTIBLE WALLS RECOMMENDED CLEARANCES Left Side 6 in 0 in 6 in Right Side 6 in 0 in 10 in Rear 10 in 10 in 12 in 2 The kettle should be installed in an adequately ventilated room with provision for adequate air supply The ventilation must employ a vent hood and exhaust fan with no direct connection between the vent duct and the kettle flue Do not obstruct the...

Page 4: ... 5 14 300 500 ELECTRICAL SUPPLY This unit is designed for connection to fixed wiring A suitably rated isolating switch with contact separation of at least 3 mm 0 12 in on both poles must be fitted to the installation and the wiring executed in accordance with the regulations listed in this manual Cable entry is at the lower rear on the right side of the appliance Access is gained by removing relev...

Page 5: ...ntal position note how the water lies in the kettle to confirm that the pan was leveled properly during installation 3 Following the To Start Pan instructions for your kettle model begin heating the water at a temperature setting of 235ºF 113ºC At this setting heating should continue until the water boils 4 To shut down the unit switch the power switch to OFF 5 Turn the tilting handwheel countercl...

Page 6: ...ndicator light located on the control console illuminates when the jacket water falls below acceptable levels When lit the main gas valve is disabled and will not function until the jacket water is refilled using the procedure in this manual f SETTnnP Mode Allows power to the controller and gas to the pilot without the kettle heating the kettle will heat once the LOW TEMP MANUAL or HIGH TEMP butto...

Page 7: ...faces d Place cover on safe flat sanitary out of theway surface or return to kettle 2 Basket Insert An optional kettle basket insert set Tri BC will assist in cooking water boiled products including eggs potatoes vegetables shell fish pasta and rice The nylon mesh liner must be used for products smaller than the basket mesh size approx 6 mm This includes rice and small pasta shapes a Allow for dis...

Page 8: ...AD AND FOLLOW ALL PRECAUTIONS ON THE LABEL OF THE WATER TREATMENT COMPOUND WARNING BEFORE REPLACING ANY PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY AND CLOSE THE MAIN GAS VALVE ALLOW FIVE MINUTES FOR UNBURNED GAS TO VENT The pressure gauge should show a vacuum of 20 to 30 inches when the kettle is cold Add grease through Zerk Fittings Liberally grease the wheel where it contacts the w...

Page 9: ...e the pH by frequently comparing the test strip color with the color chart provided in the test kit Caution Do not add excess amount of treatment compound Excess amount could cause extensive corrosion 6 As you add water to the jacket check water level to ensure that it is between minimum and maximum marks on glass or at the top of the sight glass port for models DH DHT 80 Stop adding water when it...

Page 10: ...is operating margin may result in water leakage past the seat and accumulation of deposits on the seating surface Excessive deposits may prevent the valve from operating properly and a dangerous pressure build up and equipment rupture may result MAINTENANCE AND TESTING 11 Test the operation of the safety valve on a regular basis past the seat and accumulation of deposits on the seating surface Exc...

Page 11: ... point of discharge mplete drainage of both the the discharge line ndently supported and securely so as to avoid applied stress ve t and straight as possible s freely to atmosphere where arge will be clearly visible and sk of freezing s with a plain end that is not cted of a material suitable for to temperatures of 375º F or entire length of a size equal ter than the valve outlet dule 40 pipe for ...

Page 12: ...rder g NOTE When replacing spark ignition module verify that the high voltage cable to the pilot is not damaged or frayed If damaged replace the cable and route it the same as original placement c Remove low water level control transformer or the fuse d e Replace in reverse order Ensure the low water level control relay is correctly oriented when re positioned 3 8 Removal of Tilt Switch Turn the g...

Page 13: ...he jacket should be filled REMOVAL OF BURNERS TURN THE GAS ELECTRICITY MAINS OFF 1 Remove water splash guards around the burner 2 Undo compression fitting at gas pipe to burner manifold and to the pilot 3 Disconnect electrical leads to the pilot 4 Remove the four retaining nuts securing the burner and igniter assembly to the combustion chamber Carefully support the weight of the burner manifold an...

Page 14: ...User a Temperature Controller dial setting Auth Service Rep Only b Temperature Controller calibration and offset X c Temperature Controller operation TheTemperature Controller should click when the dial is rotated to settings above and below the temperature of the kettle X SafetyValve pops open User a For air in the jacket See JacketVacuum in the Maintenance b Temperature Controller dial setting A...

Page 15: ...ESTAL 175330 1 1 4 WELDMENT CLADDING PEDESTAL 175378 1 4 WELDMENT CLADDING PEDESTAL 175337 1 1 5 PANEL SIDE PEDESTAL 175383 1 5 PANEL SIDE PEDESTAL 175336 1 1 6 SCREW MACHINE HEX HEAD 1 2 13 X 1 1 2 LONG 008679 4 4 4 7 NUT HEX 1 2 13 005603 4 4 4 8 WASHER LOCK 1 2 005657 4 4 4 9 WASHER PLAIN 1 2 005049 8 8 8 10 WASHER LOCK 8 012971 2 2 2 11 SCREW MACHINE TRUSS HEAD 8 32 X 3 8 LONG 137766 14 14 14 ...

Page 16: ...16 OM DH T DOMESTIC CE INTERNATIONAL Parts List GAS VALVE PIPING BOTTOM COMPONENTS ...

Page 17: ...FITTING COMPRESSION 90 DEG ELBOW 1 8 NPT MALE X 1 4 TUBE 004584 1 1 1 1 25 TUBE ALUMINUM 1 4 OD 006796 20 IN 20 IN 20 IN 20 IN FITTING COMPRESSION 5 8 TUBE X 1 2 NPT FEMALE 049094 1 1 1 1 SCREW TRUSS HEAD 10 32 X 3 8 LONG 004173 2 2 2 2 STRAP EMT CONDUIT 3 4 135252 3 3 3 2 COUPLING FULL 1 2 NPT 150 005722 1 1 1 1 ELBOW 90 DEG 3 8 NPT 055335 1 QUANTITY Ref Description Part 20 Gal 40 Gal 60 Gal 80 G...

Page 18: ...E BOX 104941 1 4 GASKET MODULE BOX CE 154070 1 5 MODULE IGNITION 085153 1 5 MODULE IGNITION CE 154059 1 6 NUT HEX KEPS 6 32 071289 2 7 ADAPTER CONDUIT PLASTIC MALE 123733 1 8 COVER MODULE BOX 104948 1 8 COVER MODULE BOX CE 154067 1 9 NUT HEX KEPS 8 32 069784 1 10 ANCHOR CABLE TIE SCREW MOUNTED 102231 1 11 STRAP CABLE TIE 011093 1 12 CABLE HI VOLTAGE SPARK IGNITION 096728 1 SCREW HEX BINDER HEAD 10...

Page 19: ...URNER NAT GAS OR G20 123580 1 1 1 1 3 PILOT BURNER PROPANE OR G31 128415 1 1 1 1 4 BRACKET BURNER SUPPORT 117008 2 4 BRACKET BURNER SUPPORT 117009 2 4 BRACKET BURNER SUPPORT 117010 2 2 5 BRACKET BURNER 117011 2 5 BRACKET BURNER 117012 2 5 BRACKET BURNER 117013 2 2 WASHER FENDER 1 4 132107 3 3 6 BURNER MANIFOLD AND ORIFICES NOTE 1 1 1 1 1 NOTE 1 CONTACT FACTORY WITH ELEVATION AND GAS TYPE NATURAL P...

Page 20: ...ECTION 137874 137872 1 1 FLUE MAIN BODY FRONT SECTION 149220 150927 1 2 FLUE TOP PLATE TOP SECTION 117038 1 2 FLUE TOP PLATE TOP SECTION 117029 1 2 FLUE TOP PLATE TOP SECTION 128169 1 2 FLUE TOP PLATE TOP SECTION 149222 1 3 FLUE TOP PLATE BOTTOM SECTION 117037 1 3 FLUE TOP PLATE BOTTOM SECTION 117033 1 3 FLUE TOP PLATE BOTTOM SECTION 117028 1 3 FLUE TOP PLATE BOTTOM SECTION 149236 1 4 SCREW TRUSS ...

Page 21: ...ERMINAL 2 POLE 003887 1 8 FUSE 3 0 AMP TYPE 3 AG 077853 1 9 HOLDER FUSE TYPE 3 AG 077854 1 11 SCREW ROUND HEAD MACHINE 8 32 X 1 1 4 LONG 005056 1 12 SCREW ROUND HEAD SELF TAP 6 32 X 3 8 LONG 012398 1 12 TRANSFORMER 20VA 120V PRIMARY 24V SECONDARY 137487 1 12 TRANSFORMER 40VA 208 240V PRIMARY 24V SECONDARY 137441 1 HARNESS WIRIN KETTLE CONTROL 123779 1 HARNESS WIRING CONTROL PANEL 123582 1 LABEL EL...

Page 22: ... 1 6 PC BOARD MOUNTING POST 099901 3 7 SCREW ROUND HEAD 8 32 1 1 4 005056 2 8 TRANSFORMER CE 208 230 460 TO 24V 148899 1 9 LUG GROUND 14 6 AWG 129714 1 10 SCREW HEX SLOTTED HD WITH WASHER 8 32 X 3 8 069789 6 11 NUT HEXHEAD KEPS 10 32 071256 1 12 SCREW PAN HEAD 6 32 X 3 8 009697 1 13 LABEL 3 AMP 102251 1 14 SUPPLY VOLTAGE 114316 1 15 VOLTAGE MARKERS 230 008118F 1 16 VOLTAGE MARKERS SINGLE PHASE 008...

Page 23: ... 101145 1 1 1 SPACER LIGHT MOUNT 175221 1 1 1 Bracket Light Mount 175222 1 1 1 Classic Controls Overlay 175303 1 1 1 Parts List FRONT PANEL COMPONENTS For Advanced Control Models QUANTITY Ref Description Part 20 Gal 40 Gal 60 Gal 1 2 ALUMINUM KNOB 174829 1 1 1 2 POWER SWITCH 174871 177910 1 1 1 3 INDICATOR LIGHT RED 116383 1 1 1 4 ADVANCED CONTROLS 174837 1 1 1 5 HEX NUT 101145 1 1 1 6 INDICATOR L...

Page 24: ...762 1 1 1 9 ASSEMBLY BEARING HOUSING 149788 1 10 BEARING BALL 009765 2 2 2 2 11 GEAR WORM 3 4 BORE 012026 1 1 1 1 12 WASHER SHIM 1 3 8 ID 012039 2 2 2 13 SCREW SET SOCKET 012060 1 1 1 1 14 PIN ROLL 1 4 DIA X 1 1 4 LONG 012614 3 3 3 3 15 RING BASIC INTERNAL 013483 2 2 2 2 16 GEAR 3 BORE 92 TEETH 013609 1 1 1 1 17 HANDLE CRANK 3 4 BORE 013617 1 1 1 1 18 SHAFT HANDWHEEL 3 4 OD X 13 1 2 LONG 013624 1 ...

Page 25: ...1 10 1 2 NPT TO 1 2 BSPT ADAPTER 116392 1 11 ELBOW 90 DEG UNION 1 2 NPT 005495 1 12 FLEXIBLE TUBE GAS 1 2 OD 35 LONG DH 20 154291 1 12 40 FLEX TUBE GAS 1 2 OD DH 40 DH 60 154106 1 13 GAS VALVE CE MARK G31 160796 1 13 GAS VALVE CE MARK G20 160776 1 14 FITTING COMPRESSION 5 8 TUBE X 1 2 MPT 049093 2 15 TUBE GAS PIPING SUPPLY SIDE DH 20 145038 1 15 TUBE GAS PIPING SUPPLY SIDE DH 40 145040 1 15 TUBE G...

Page 26: ...PSI 175196 1 KBA TRUNNION DHT 80 2 TDO 50 PSI 175197 1 REPLACEMENT COMBUSTION CHAMBERS CHAMBER COMBUSTION 122092 1 CHAMBER COMBUSTION 122093 1 DIVERTER FLUE GAS 062105 2 DIVERTER FLUE GAS 062106 2 CHAMBER COMBUSTION 122094 1 DIVERTER CENTER PLATE FLUE GAS 049716 2 DIVERTER CENTER PLATE FLUE GAS 049718 2 2 DIVERTER SIDE PLATE FLUE GAS 049717 2 2 CHAMBER COMBUSTION 122094 1 DIVERTER TOP PLATE 154028...

Page 27: ...27 OM DH T DOMESTIC CE INTERNATIONAL Wiring Diagram Domestic For Classic Control Models ...

Page 28: ...28 OM DH T DOMESTIC CE INTERNATIONAL Wiring Diagram Domestic For Advanced Control Models ...

Page 29: ...29 OM DH T DOMESTIC CE INTERNATIONAL Wiring Diagram CE ...

Page 30: ...30 OM DH T DOMESTIC CE INTERNATIONAL Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...

Reviews: