81
--MENU SELECTION---
*Operator
Technician
^ v Sel ESC
End
Machine settings
Esc
Esc
Set free
v
end, glo
b
al
Energy sa
v
ing
v
^
v
^
v
^
v
^
Filling / Clean
Esc
4
Sel
Esc
Esc
Esc
Esc
Esc
Esc
Set day(s)
Period 1
v
^
Set time
v
^
Set temperat
u
re
v
^
Set doorlight
v
^
Sel
Sa
v
e energy On/Off
Sel
Esc
Sel
Esc
Period 1
Sel
Esc
Sa
v
e energy
1=On / 0=Off_1
(-) (+) -> OK
Sel
Set start day:
(Mo=0, S
u
=6, All=7):1
(-) (+) Esc OK
Sel
Set start time:
Time: 00:00
(-) (+) -> OK
Set end time:
Time: 00:00
(-) (+) -> OK
Set end day:
(Mo=0, S
u
=6, All=7):1
(-) (+) Esc OK
Sel
Esc
Set temperat
u
re
Temp.: 000
(-) (+) -> OK
Sel
Esc
Set doorlight
1=On / 0=Off:1
(-) (+) -> OK
OK
OK
OK
OK
OK
-----SHORTCUTS-----
*(1)=Rinse 3=Counter
(2)=Test 4=Menu
Start
(1) (2) (3)
(4)
Gallery 310
Setting energy saving periods
•
Follow this diagram to define one or
more energy saving periods (up to
seven periods).
•
Setting a period means scheduling
the machine to reduce the
temperature for the boiler heating to
the temperature set in ‘Set
temperature’ and to switch off the
door light, if ‘Set doorlight’ is
enabled.
Temperature should never
be set below 65 °C.