41
01.2003
Series 03
Trouble shooting
REMEDY
- Remove the combi-trough, carry out the cleaning
process and rinse the dispenser
- Clean the cooling compartment
- Clean the combi-trough and the trough box, then
rinse the dispenser (if the dispenser is not cleaned
within 4 hours the delivery is blocked)
- Change the programming by means of the service
panel
- Clean combi-trough (see chapter 'Maintenance').
If the malfunction cannot be cleared call a Service
Technician.
- Carry out the rinsing operation on the left hand
side (see chapter 'Maintenance'). If the malfunction
cannot be cleared call a Service Technician.
- Carry out the rinsing operation on the right hand
side (see chapter 'Maintenance'). If the malfunction
cannot be cleared call a Service Technician.
- Mount combi-trough correctly.
If the malfunction cannot be cleared call a Service
Technician.
CAUSE
- The combi-trough has not been cleaned
- The cooling compartment has not been cleaned
for more than 184 hours
- 'clean' has been displayed and the combi-
trough has been removed
- The beverage delivery has been blocked
- Diaphragm sluggish
- Sluggish left mixer
- Sluggish right mixer
- Combi-trough has not been mounted correctly
FAULT/DISPLAY
Display shows 'clean'
(the ON/OFF LED and
the 'empty' LEDs are
flashing)
Display shows 'sanit' (the
ON/OFF LED and the
'empty' LEDs are
flashing).
Delivery is blocked
Display shows 'Flush'
(the ON/OFF LED and
the 'empty' LEDs are
flashing)
Display shows 'bloc'
ERR15 is displayed
on the service panel
ERR19 is
displayed on the
service panel
ERR21 is
displayed on the
service panel
ERR23 is displayed
on the service panel
Summary of Contents for Cafitesse 400
Page 1: ...OPERATING INSTRUCTIONS B 1983 01 2003 ...
Page 2: ......