26
12.03
TECHNICAL DATA
The correct values for the different dispenser types are given on the rating plate.
Dimensions:
Height:
645 mm
Width:
210 mm
Depth:
455 mm
Weight:
21 kg
Water connection:
Drinking water line with stop valve. Connection to hot water
supply via copper pipes only.
Supply system requirements:
Temperature:
max. 75 °C
Dynamic pressure:
min. 0,8 bar
Static pressure:
max. 10 bar
Water filling capacity:
6.5 l, open boiler.
Beverage capacity:
approx. 300 cups/hour at 220 V/3 kW
or approx. 200 cups/hour at 220 V/2kW
Concentrate capacity:
Coffee pack container 2 l.
Electric connection:
Only via power supply plug, otherwise a contact
breaking device (min. 3mm) controlling all poles
must be installed in the power supply system.
An earth connection must be made.
Length of the power
supply cable:
approx. 1.80 m
Acoustic emission:
The A-weighted sound pressure level of the dispenser
is below 70 dB.
Further installation conditions: Installation height:
up to 2000 m
Ambient temperature:
10°C, max,. 32 °C
Options:
Operating panel with counter and key switch, drip tray assembly,
flexible pressure hose with 3/8" UNF, R3/4" or R3/8" connection,
heating plate
Accessories:
Cleaning brush and connecting piece for water inlet
The dispenser is marked with the CE label
(Low voltage directive, directive for electromagnetic compatibility)
Subject to changes!