background image

4

TO FILTER/VALVE PUMP PORT

TO TOP PUMP PORT (DISCHARGE)

MODEL GEN 240

This filter model is designed for a hard plumbing installa-
tion and is provided with a special high flow return fitting
with a 1-1/2" pipe socket for installing 1-1/2" PVC pipe.

INSTALL RETURN FITTING

MODEL GEN 240 ONLY

Discard the EYEBALL RETURN FITTING provided with
your pool and replace it with the HIGH FLOW RETURN
FITTING
 as shown.

CORRUGATED HOSE

CONNECTION WITH WIRE CLAMP

TO FILTER/VALVE RETURN PORT

adaptor (56) and push threaded end through the wall
from inside pool.  Place the second gasket over the
threads now exposed outside the pool.

2. Hold the return fitting adaptor (56) and thread the

union adaptor (62) onto it and tighten firmly.  Hint:
Using an oil filter wrench to tighten the union adaptor
will make the job easier.

3. Your pressure type pool cleaner will attach to the

return fitting adaptor.

HARD PLUMB INSTALLATIONS

Using a 1-1/2" Schedule 40 PVC pipe with ends cut
square, remove any burrs.  Cut pipe to length as re-
quired between joints and loosely assemble for proper fit
prior to solvent welding.  Slip the union nut (65) onto the
pipe with the female threads facing the union adaptor
(62).  Then, solvent weld the union socket (64) onto the
pipe using primer and PVC/ABS solvent cement.  DO
NOT Allow solvent cement to contact the sealing
surface of the union socket.  When dry, assemble the
connections and tighten firmly by hand.

Locate a board large enough to cover return fitting cut-
out.  From inside of pool, use the board to hold liner
against cut-out in pool wall.  Keep hands away from hole
to avoid injury.  From outside of pool, use the cut-out as
guide and cut away liner with a razor knife.

INSTALLATION

(without pressure type pool cleaner)

1.  Slip a gasket (61) over the threads of the return fitting

(60) and push threaded end through the wall from
inside pool.  Place the second gasket over the
threads now exposed outside the pool.

2.  Hold the return fitting (60) so the opening is facing

away from the skimmer and slightly downward.
Thread the union adaptor (62) onto the return fitting
and tighten firmly.  Hint:  Using an oil filter wrench to
tighten the union adaptor will make the job easier.

INSTALLATION

(with pressure type pool cleaner)

1. Slip a gasket (61) over the threads of the return fitting

RETURN LINE

INSTALLATION

HI- FLOW

RETURN PAK

PUMP DISCHARGE

INSTALLATION

 (HARD PLUMB)

OPTION FOR HARD PLUMBING

If your option is to hard plumb the pump discharge to
filter inlet, it will be necessary that you order a “hard
plumb adaptor” (P/N 348-1036) and one “Clamp” (P/N
387-1024).  Refer to “Cut and loosely assemble piping”
and “Solvent welding” for PVC piping assembly, then
install as shown.

INSTALL RETURN LINE

An 8 foot long hose is provided for filter Model GEN 180
and a special high flow return fitting with filter Model
GEN 240  for the return line.

MODEL GEN 180 ONLY

Slip a hose clamp over the ends of the hose and push
one end onto the filter/valve RETURN port and the other
end onto the pool RETURN fitting.  Tighten clamps
firmly using a flathead screwdriver or 5/16" nutdriver.

POOL RETURN

FITTING

Summary of Contents for 0-1802-019

Page 1: ...1775 the original portable pool Shown with Power Pak III not included Generation II Cartridge Filter with 6 Position Valve Model GEN 180 Item No 0 1802 019 Model GEN 240 Item No 0 1802 022 Owner s Gu...

Page 2: ...tion of debris and moisture ACCESSIBILITY The circulation system components should be installed to allow accessibility for inspection repair or replace ment DO NOT alter the pump electrical cord in an...

Page 3: ...ocks provide firm support and keeps standing water and weeds away from electrical parts DO NOT install your filter and pump directly on the ground surface Settling and stressing circulation lines may...

Page 4: ...h to cover return fitting cut out From inside of pool use the board to hold liner against cut out in pool wall Keep hands away from hole to avoid injury From outside of pool use the cut out as guide a...

Page 5: ...disc 66 between o ring 63 and union socket Retighten union nut onto union adaptor firmly INSTALL SUCTION LINE An 8 foot long hose is provided for filter Model GEN 180 and a hard plumb adaptor with cl...

Page 6: ...or twice during this initial stage of filtering the new raw water After this initial filtering stage the cleaning intervals will be extended less frequent allowing longer time periods between cleanin...

Page 7: ...g these vital areas 7 9 CLEAN CARTRIDGES Attach the BLASTER NOZZLE to a garden hose Position cartridge in an upright position supporting with one hand when cleaning Hold the blaster nozzle away from t...

Page 8: ...S IS NOT COVERED BY PRODUCT WARRANTY LUBE VALVE SHAFT To lubricate the O Ring on the valve shaft depress valve handle fully and apply lubricant on the shaft between handle and valve cover Then rotate...

Page 9: ...Y CARD TO TOP PUMP PORT TO POOL RETURN TO FRONT PUMP PORT TO SKIMMER TO WASTE HI FLOW RETURN PAK NOTE CARTRIDGE CONFIGURATION FOR GEN 180 SHOWN See Parts List for GEN 240 part quanities EXPLODED VIEW...

Page 10: ...Cap Gasket Drain Fitting Nut O Ring 1 287 I D Drain Fitting Threaded Adaptor Assembly Manifold Support Manifold Collector Bottom GEN 180 Manifold Collector Bottom GEN 240 Manifold Elbow GEN 180 Manif...

Page 11: ...1 1 1 1 1 2 1 1 1 1 1 Return Fitting Adaptor 36 Band Clamp Hard Plumb Adaptor 28 Band Clamp Return Fitting Return Gasket Union Adaptor O Ring 50mm I D Union Socket Union Nut Winterize Disc Pin Retaine...

Page 12: ...hemically out of filter balance 3 Chemically treat and balance pool water condition 5 Short filter cycles 1 Cartridges clogged with 1 Clean cartridges contaminants or algae 2 Clean cartridges Refer to...

Reviews: