4
TO FILTER/VALVE PUMP PORT
TO TOP PUMP PORT (DISCHARGE)
MODEL GEN 240
This filter model is designed for a hard plumbing installa-
tion and is provided with a special high flow return fitting
with a 1-1/2" pipe socket for installing 1-1/2" PVC pipe.
INSTALL RETURN FITTING
MODEL GEN 240 ONLY
Discard the EYEBALL RETURN FITTING provided with
your pool and replace it with the HIGH FLOW RETURN
FITTING as shown.
CORRUGATED HOSE
CONNECTION WITH WIRE CLAMP
TO FILTER/VALVE RETURN PORT
adaptor (56) and push threaded end through the wall
from inside pool. Place the second gasket over the
threads now exposed outside the pool.
2. Hold the return fitting adaptor (56) and thread the
union adaptor (62) onto it and tighten firmly. Hint:
Using an oil filter wrench to tighten the union adaptor
will make the job easier.
3. Your pressure type pool cleaner will attach to the
return fitting adaptor.
HARD PLUMB INSTALLATIONS
Using a 1-1/2" Schedule 40 PVC pipe with ends cut
square, remove any burrs. Cut pipe to length as re-
quired between joints and loosely assemble for proper fit
prior to solvent welding. Slip the union nut (65) onto the
pipe with the female threads facing the union adaptor
(62). Then, solvent weld the union socket (64) onto the
pipe using primer and PVC/ABS solvent cement. DO
NOT Allow solvent cement to contact the sealing
surface of the union socket. When dry, assemble the
connections and tighten firmly by hand.
Locate a board large enough to cover return fitting cut-
out. From inside of pool, use the board to hold liner
against cut-out in pool wall. Keep hands away from hole
to avoid injury. From outside of pool, use the cut-out as
guide and cut away liner with a razor knife.
INSTALLATION
(without pressure type pool cleaner)
1. Slip a gasket (61) over the threads of the return fitting
(60) and push threaded end through the wall from
inside pool. Place the second gasket over the
threads now exposed outside the pool.
2. Hold the return fitting (60) so the opening is facing
away from the skimmer and slightly downward.
Thread the union adaptor (62) onto the return fitting
and tighten firmly. Hint: Using an oil filter wrench to
tighten the union adaptor will make the job easier.
INSTALLATION
(with pressure type pool cleaner)
1. Slip a gasket (61) over the threads of the return fitting
RETURN LINE
INSTALLATION
HI- FLOW
RETURN PAK
PUMP DISCHARGE
INSTALLATION
(HARD PLUMB)
OPTION FOR HARD PLUMBING
If your option is to hard plumb the pump discharge to
filter inlet, it will be necessary that you order a “hard
plumb adaptor” (P/N 348-1036) and one “Clamp” (P/N
387-1024). Refer to “Cut and loosely assemble piping”
and “Solvent welding” for PVC piping assembly, then
install as shown.
INSTALL RETURN LINE
An 8 foot long hose is provided for filter Model GEN 180
and a special high flow return fitting with filter Model
GEN 240 for the return line.
MODEL GEN 180 ONLY
Slip a hose clamp over the ends of the hose and push
one end onto the filter/valve RETURN port and the other
end onto the pool RETURN fitting. Tighten clamps
firmly using a flathead screwdriver or 5/16" nutdriver.
POOL RETURN
FITTING