“READ ALL INSTRUCTIONS”  Failure to follow these important
safety instructions and other basic safety precautions may result
in serious personal injury.

Before you begin installing your filter, refer to your pump
owners guide for very important installation and electri-
cal information related to your filter.

ELECTRICAL/BUILDING PERMIT

Local building codes may require obtaining an electrical
or building permit and may have regulations on set
backs and barriers that must be followed.

ELECTRICAL

We recommend you have a qualified electrical contrac-
tor install the electrical power supply as specified in your
pump instructions.

INSTALLED LOCATION

Position filter, pump and any other related components
a minimum of 4 feet from pool to prevent their being
used as a means to climb into the pool by young chil-
dren.  DO NOT store toys, chairs, tables, containers or
other objects within 4 feet of the pool for the same
reason.

 WARNING

SEVERE ELECTRICAL SHOCK could result if you
install your filter and pump on a deck or above pool
water level.  They could fall into the water, causing
severe shock or electrocution.  DO NOT install on a
deck or other surface at, above or slightly below the top
rail of the pool.

PROPERLY SUPPORTED

Filter, pump and any other related components should
be properly supported to prevent damage from misalign-
ment, settlement, vibration and mounted so as to
minimize the potential for the accumulation of debris and
moisture.

ACCESSIBILITY

The circulation system components should be installed
to allow accessibility for inspection, repair or replace-
ment.

DO NOT alter the pump electrical cord in any way or
change the plug end to any style.

DO NOT use an extension cord(s).  Severe electrical
shock may occur.

IMPORTANT SAFETY INSTRUCTIONS

PREVENT SEVERE SHOCK

To prevent the risk of severe electrical shock, plug your
pump cord end into a grounding type receptacle pro-
tected by a ground fault circuit interrupter (GFCI).
Contact a qualified electrician if you cannot verify that
the receptacle is protected by a GFCI.

DO NOT allow children to operate or play around this
product unless they are closely supervised by adults at
all times.

Replace damaged cord immediately to reduce the risk of
electrical shock.

DO NOT BURY CORD

An exposed cord may accidentally become damaged or
severed by a sharp object or shovel resulting in severe
electrical shock.  Position cord to prevent accidental
damage from lawn mowers, hedge trimmers or other
equipment.

BARE FEET/WET GROUND

This is a dangerous combination around electrical
equipment.  Always be sure the ground under your feet
and body is dry before you touch electrical equipment.
Failure to heed this warning may cause severe personal
injury or electrocution due to severe electrical shock.

 WARNING

Avoid direct water spraying with a garden hose around
electrical outlets, pump or any other electrical devices.
Severe electrical shock or electrocution may occur.

SERVICING YOUR PUMP

Always unplug your pump from the receptacle before
servicing, adjusting or repairing.

WARNING 

Summary of Contents for 0-1802-019

Page 1: ...1775 the original portable pool Shown with Power Pak III not included Generation II Cartridge Filter with 6 Position Valve Model GEN 180 Item No 0 1802 019 Model GEN 240 Item No 0 1802 022 Owner s Gu...

Page 2: ...tion of debris and moisture ACCESSIBILITY The circulation system components should be installed to allow accessibility for inspection repair or replace ment DO NOT alter the pump electrical cord in an...

Page 3: ...ocks provide firm support and keeps standing water and weeds away from electrical parts DO NOT install your filter and pump directly on the ground surface Settling and stressing circulation lines may...

Page 4: ...h to cover return fitting cut out From inside of pool use the board to hold liner against cut out in pool wall Keep hands away from hole to avoid injury From outside of pool use the cut out as guide a...

Page 5: ...disc 66 between o ring 63 and union socket Retighten union nut onto union adaptor firmly INSTALL SUCTION LINE An 8 foot long hose is provided for filter Model GEN 180 and a hard plumb adaptor with cl...

Page 6: ...or twice during this initial stage of filtering the new raw water After this initial filtering stage the cleaning intervals will be extended less frequent allowing longer time periods between cleanin...

Page 7: ...g these vital areas 7 9 CLEAN CARTRIDGES Attach the BLASTER NOZZLE to a garden hose Position cartridge in an upright position supporting with one hand when cleaning Hold the blaster nozzle away from t...

Page 8: ...S IS NOT COVERED BY PRODUCT WARRANTY LUBE VALVE SHAFT To lubricate the O Ring on the valve shaft depress valve handle fully and apply lubricant on the shaft between handle and valve cover Then rotate...

Page 9: ...Y CARD TO TOP PUMP PORT TO POOL RETURN TO FRONT PUMP PORT TO SKIMMER TO WASTE HI FLOW RETURN PAK NOTE CARTRIDGE CONFIGURATION FOR GEN 180 SHOWN See Parts List for GEN 240 part quanities EXPLODED VIEW...

Page 10: ...Cap Gasket Drain Fitting Nut O Ring 1 287 I D Drain Fitting Threaded Adaptor Assembly Manifold Support Manifold Collector Bottom GEN 180 Manifold Collector Bottom GEN 240 Manifold Elbow GEN 180 Manif...

Page 11: ...1 1 1 1 1 2 1 1 1 1 1 Return Fitting Adaptor 36 Band Clamp Hard Plumb Adaptor 28 Band Clamp Return Fitting Return Gasket Union Adaptor O Ring 50mm I D Union Socket Union Nut Winterize Disc Pin Retaine...

Page 12: ...hemically out of filter balance 3 Chemically treat and balance pool water condition 5 Short filter cycles 1 Cartridges clogged with 1 Clean cartridges contaminants or algae 2 Clean cartridges Refer to...