19
18
1. Handling
General advices
- For cleaning the instrument please do not use abrasive cleaner but a dry or
wet piece of cloth.
- Please store the measuring instrument in a dry and clean place.
- Avoid any force like shocks or pressure to the instrument.
- Do not use force to connect the probe or interface plugs in. The interface
plug is different from the probe plug.
- lf no sensor is connected to the instrument while switching on „open“
shows on the display (Please refer to chapter error codes / troubleshooting).
- A retractable stand on the back of the instrument allows it to be used as a
bench top instrument.
1.1 Setting to work
Before switching on the instrument connect the probe/s to the instrument
1.2 Switching on & off
By operating the ON/OFF-key the instrument switches on or off. After switching on, the instrument indica
-
tes a full segment test for 15 seconds, then it starts to function in measurement mode indicating the actual
measurement value.
1.3 Menu
The adjustments of the instruments function: measurement value, calibration of probes, deactivation of
channels, for example, are selected from the menu structure. Enter into the main menu by push ing (ENTER/
MENUE). Use the up and down keys (
) to select the required menu. Push (ESC) to revert back to the
measuring mode.
1. (ESC) key
2. Up and down keys
3. (ENTER/MENUE) key
1.
3.
2.
UniT
°C
°F
Lo6
ChnI
oFF
CAL
Prob
L in 2
T1-T2
on
Menu structure
nur / only
755-LOG-EX
oFF
on
AUTo SPoT
Add nLo6
2)
2)
oP 1
oP 2
2)
CoFF
nur / only
P710-EX/715-EX
P755-LOG-EX
nur / only
2-Kanal Geräte
nur / only
2-Kanal Geräte
P
J
K
L
N
R
S
T
1 S
2 S
5 S...
Add nLo6
1.3.1 Changing units from °C to °F
To change the measuring unit push [ENTER/MENUE]. Use the up and down keys
(
)
to select Unit. Push
again [ENTER/MENUE]. On the left corner of the display appears a small 1, which indicates the selected
channel. For changing the channel use the up and down keys
(
)
. Push [ENTER/MENUE] to confirm. On
the right corner of the display appears °C or °F, or %rH, td or gm³(depending on the selected probe). Use the
up and down keys
(
)
again to adjust the requested measuring unit and push [ENTER/MENUE] to confirm.
Push [ESC] to be back in the measuring mode.
1.3.2 Probe selection / (Prob)
only for P710-EX / P715-EX / P755-LOG-EX
Push (ENTER/MENUE) to change a probe. Use the up and down keys (
) to select Prob. Push (ENTER/
MENUE) to confirm.
On the left corner of the display appears a small
1
, which indicates the selected channel.
For changing the channel use the up and down keys (
). Push again (ENTER/MENUE)
to confirm. On the right corner of the display appears the active probe. Use the up and
down keys (
) to change the probe. Push (ENTER/MENUE) to confirm the requested
probe. Push (ESC) to be back in the measuring mode.
MENUE
UniT
Prob
L in 2
CAL
Lo6
Chnl
nur / only
P710-EX/715-EX
P755-LOG-EX
nur / only
P755-LOG-EX
nur / only
2-Kanal Geräte
nur / only
2-Kanal Geräte
Push (ENTER/MENUE) to confirm. Push (ESC) to revert back to the measuring mode.
Note:
Please check the probe selection to be sure that the correct probe is entered. If a measurement value
is changed with the ENTER-key at the menu Prob, the standard calibration will be automatically used.
Measurement
Probe selection
LC-Display
Suitable for these types
(Prob)
of measuring instruments:
............................................................................................................................................................
Temperature
Pt100 (RTD)
P710-EX/P715-EX/P755-LOG-EX
............................................................................................................................................................
Temperature
Fe-CuNi Typ J
P710-EX/P715-EX/P755-LOG-EX
............................................................................................................................................................
Temperature
NiCr-Ni Typ K
P710-EX/P715-EX/P755-LOG-EX
............................................................................................................................................................
Temperature
Fe-CuNi Typ L
P710-EX/P715-EX/P755-LOG-EX
............................................................................................................................................................
Temperature
NiCrSi-NiSi Typ N
P710-EX/P715-EX/P755-LOG-EX
............................................................................................................................................................
Temperature
Pt13Rh-Pt Typ R
P755-LOG-EX
............................................................................................................................................................
Temperature
Pt10Rh-Pt Typ S
P755-LOG-EX
............................................................................................................................................................
Temperature
Cu-CuNi Typ T
P710-EX/P715-EX/P755-LOG-EX
............................................................................................................................................................
MENUE
UniT
Prob
L in 2
CAL
Lo6
Chnl
nur / only
P710-EX/715-EX
P755-LOG-EX
nur / only
755-LOG-EX
nur / only
2-Kanal Geräte
nur / only
2-Kanal Geräte