HOW TO DRAIN THE DOSATRON (in case of frost protection)
- Turn off the water supply and let the pressure drop to zero.
- Remove the injection assembly.
- Remove the bell and the motor piston.
- Disconnect the water inlet and outlet fittings.
- Remove the lower pump body from the mounting bracket and empty any
remaining water.
- The DOSATRON can now be reassembled, having first cleaned the seal.
FITTING THE SUCTION TUBE
If the DOSATRON has already been used, please
imperatively refer to
§ PRECAUTIONS.
For Ø 4 (Fig. 12) :
- Unscrew the nut at the bottom of the injection assembly.
- Push the suction hose through the nut then the ferrule, as displayed on the
diagram, letting the hose stick out from the ferrule by a few millimetres.
- Push then the hose inside the barbed fitting and re-tighten the nut.
For Ø 16 (Fig. 13) :
- Unscrew the nut at the bottom of the injection assembly and put it onto
the tube.
- Push the hose firmly into the barbed fitting and re-tighten the collar.
For Ø 20 (Fig. 14) :
- Using a screwdriver, unscrew the collar (
Fig. 12-C)
mounted on the
suction hose.
- Push the hose firmly into the barbed fitting and re-tighten the collar.
Fig. 13
Fig. 12
Fig. 14
Ø 16
Ø 4
Ø 20
Summary of Contents for D8IL2EX
Page 2: ...Manuel d utilisation Owner s manual D8 INDUSTRY LINE ATEX...
Page 3: ...DOSATRON INTERNATIONAL S A S 3 NOTES...
Page 4: ...DOSATRON INTERNATIONAL S A S 4 Fran ais Page 5 English Page 35 Annexe enclosure Page 64 FR EN...
Page 34: ...DOSATRON INTERNATIONAL S A S 34 FR NOTES...
Page 68: ...DOSATRON INTERNATIONAL S A S 68 Limite viscosit Viscosity curves 68 71...